Chapter 4 Troubleshooting and Diagnostics

IPmux-1/1EInstallation and Operation Manual

 

 

 

 

 

 

 

 

E1 over UTP

 

E1 Statistics

 

 

 

 

 

LOS:

 

0

 

 

LOF (Red)

 

0

 

 

LCV:

 

0

 

 

RAI (Yellow)

 

0

 

 

AIS:

 

0

 

 

FEBE:

 

0

 

 

BES:

 

0

 

 

SS:

 

0

 

 

SES:

 

0

 

 

UAS:

 

0

 

 

LOMF:

 

0

 

 

Time Since:

700

sec ------------------

Valid Intervals

1---

1. Interval

0

 

 

 

ESC> Exit

N. Next Inv

 

 

 

 

 

 

 

 

 

Figure 4-1.

E1 Statistics

 

Note E1/T1 statistics are monitored and saved under consecutive Intervals. Each Interval is 15 minutes long. There are 96 intervals, which represent the last 24 hours. Whenever a new Interval is started, the counters are reset to zero. The old interval shows the total of alarms that occurred during its 15-minute period.

The current active Interval is always marked as Interval 0 (you will see that the Time Since counter is running). The previous Interval is marked as 1 and so on. The E1/T1 statistic counters cannot be reset manually. The user can browse the stored Intervals by pressing N for the Next Interval or P for the Previous Interval.

4-6

Performance Monitoring and Troubleshooting Statistics

Page 103
Image 103