Cisco Systems IPMUX-1E operation manual Ses

Models: IPMUX-1 IPMUX-1E

1 217
Download 217 pages 12.67 Kb
Page 108
Image 108

IPmux-1/1EInstallation and Operation Manual

Chapter 4 Troubleshooting and Diagnostics

 

 

 

 

 

 

 

 

Table 4-3. E1/T1 Alarms (Cont.)

 

 

 

 

 

 

 

 

 

Alarm

Description

 

 

 

 

 

 

 

SES

A Severely Errored Second is a second containing one of the following:

 

 

 

 

 

 

 

 

 

 

320 or more CRC errors events

 

One or more OOF defect

 

One or more AIS events occurred (T1 only)

 

The SES counter will be cleared after reaching 10 and an UAS will then be activated.

 

Recommendations:

 

 

 

 

 

 

 

 

 

Check physical link integrity. See also ES alarm recommendation.

 

 

 

 

 

 

UAS

Unavailable Second parameter refers to the number of seconds during which the interface is unavailable. The UAS counter will start increasing after

 

 

 

occurrences and will be deactivated as a result of 10 consecutive seconds without SES. After SES clearance the UAS counter will then

 

10 consecutive SES

 

diminish 10 seconds from the overall count.

 

Recommendations:

 

 

See above recommendations.

 

 

 

LOMF

A Loss of Multi Frame indicates there is no sync on the multi frame mode, i.e., the receiving device is unable to detect the four ABCD bits pattern on

 

 

 

for two consecutive multi frames. Available only for E1 Multi-Frame mode (CAS).

 

TS16 MSB in frame 0

 

Recommendations:

 

 

 

 

 

Check physical link integrity, signaling method (CAS enable only), and framing-related parameters.

 

 

 

 

 

 

 

 

 

Performance Monitoring and Troubleshooting Statistics4-11