Appendix E Configuration Menus

IPmux-1/1EInstallation and Operation Manual

 

 

T1 Configuration

Main Menu

2. Configuration (T1)

2.E1/T1 Configuration

Note

 

T1 CONFIGURATION

 

1.

Channel Status

Enable

2.

Transmit Clock Source

Adaptive

3.

Loopback State

Disable

4.

Line Type

T1-ESF

5.

Line Code

B8ZS

6.

Line Mode

DSU

7.

Line Length (ft)/Tx Gain (dB)

0-133

8.

Restore Time

1 second

9.

Idle Code

7E

A. Uplink Fail Alarm Behavior

Cond.

B. Signaling Mode

CAS enable

C. Cond. Data Pattern

7F

D. Cond. CAS (AB/ABCD) Pattern

01

E. Cond. CAS first 2.5 sec pattern(FF=NULL) FF

ESC. Exit

Select item from the menu.

Figure E-25. T1 Physical Layer Configuration Menu

When “unframed” mode is selected, the Restore Time, Idle Code, Signaling Mode, Cond Data Pattern, Cond CAS (AB/ABCD) Pattern and Cond. CAS first 2.5 sec pattern (FF=NULL) fields are not present.

When CAS Disabled is selected, the Cond CAS Pattern and Cond. CAS first 2.5 sec pattern (FF=NULL) fields are not present.

Table E-13. T1 Configuration Parameters

Parameter

Possible Values

Remarks

 

 

 

Channel Status

Enable

Detection of LOS alarm

 

Disable

No detection of LOS alarm

 

 

Default: Enable

 

 

 

Transmit Clock Source

Adaptive

Adaptive clock regeneration

 

Loopback

T1 recovered receive clock is used as the transmit

 

 

clock

 

Internal

Local clock source is used

 

 

Default: Adaptive

 

 

 

E-20 IPmux-1 E1/T1 Configuration