IPmux-1/1E Installation and Operation Manual Appendix E Configuration Menus
IPmux-1E Configuration E-25
Analog Configuration
ANALOG CONFIGURATION
1. Clock Source Adaptive
2. Far End Type E1
3. Channel Configuration >
4. Signaling Profile Configuration >
5. Signaling Feedback
6. Signaling Mode
7. Wiring
ESC. Exit
+----------------------------------------+
|NOTICE: The connection must be disabled |
|before changing the Clock Source or the |
| Far End Type! |
+----------------------------------------+
Select item from the menu.

Figure E-28. Analog Configuration Menu

Table E-16. Analog Configuration

Parameter Possible Values Remarks
Clock Source Internal
Adaptive
Local clock source is used
Adaptive clock regeneration
Far End Type E1
T1-ESF, T1-D4
Sets A-Law/µ-Law and TDMoIP
encapsulation mode
Channel Configuration Next screen
Signaling Profile Configuration Next screen
Signaling Feedback Valid only for FXO
Signaling Mode Type1, Type2, Type3, Type5
(SSDC5)
Valid only for E&M
Wiring 2-Wire, 4-Wire Valid only for E&M

Main Menu
2. Configuration (Analog)
2. Analog Configuration