IPmux-1/1EInstallation and Operation ManualAppendix E Configuration Menus

Table E-13. T1 Configuration Parameters (Cont.)

Parameter

Possible Values

Remarks

 

 

 

Loopback State

Internal

Data received from the IP network side is looped back

 

 

to the network transmit line. An unframed all ‘1’ code

 

 

(AIS) is transmitted in the T1 Tx path toward the PBX.

 

 

Incoming data from the PBX is ignored.

 

External

Data received from the PBX at the receive T1 line is

 

 

looped back to the T1 Tx path (toward the same PBX),

 

 

and continues its way to the IP network. Data coming

 

 

from the IP network is ignored.

 

Disable

No loopback – Regular operation

 

 

Default: Disable

 

 

 

Line Type

 

Framing mode and operation mode for each

 

 

configuration:

 

T1-D4

Framer is configured to T1-D4 mode. Operation mode

 

 

is set by Signaling mode field #6 to either Fractional or

 

 

Fractional with CAS (see Chapter 1).

 

T1-ESF

Framer will be configured to T1-ESF mode. Operation

 

 

mode will be set by signaling mode field #6 to either

 

 

Fractional or Fractional with CAS (see Chapter 1).

 

Unframed

Framer will be configured to pass through mode and

 

 

the operation mode will be set to unframed (see

 

 

Chapter 1).

 

 

Default: T1-ESF

 

 

 

Line Code

B7ZS, B8ZS, AMI

Default: B8ZS

 

 

 

Line Mode

DSU, CSU

Default: DSU

 

 

 

Line Length / Tx

DSU: 0-133 ft, 134-266 ft,

Default: 0 to 133 ft

Gain

267-399 ft, 400-533 ft,

 

 

534-655 ft

 

 

CSU: 0 dB, -7.5 dB,

 

 

-15 dB, -22.5 dB

 

 

 

Default: 0 dB

 

 

 

Restore Time

1 second,

Selects the T1 red alarm recovery time

 

10 seconds

Default: 1 second

 

 

 

Idle Code

00 to FF

Inserted into unused timeslots by IPmux-1 at the

 

 

transmit path towards T1 equipment

 

 

Note: This field will not appear if “unframed” is

 

 

selected in the Line Type field.

 

 

Default: 7E

 

 

 

IPmux-1 E1/T1 Configuration

E-21

Page 164
Image 164
Cisco Systems IPMUX-1E Framer will be configured to T1-ESF mode. Operation, Fractional or Fractional with CAS see Chapter