IPmux-1/1EInstallation and Operation ManualAppendix E Configuration Menus

 

 

 

 

Table E-27. E1/T1 Statistics (Cont.)

 

 

 

 

 

 

 

 

Alarm

Failure

 

Comments

 

 

 

 

 

 

 

 

DM

Degraded

 

A Degraded Minute is calculated by collecting all of the available seconds,

 

 

 

Minutes

 

subtracting any SESs and sorting the result in 60 second groups

 

 

 

 

 

A Degraded Minute is a 60 second group in which the cumulative errors

 

 

 

 

 

during the 60-second interval exceed 1x10-6

 

 

 

 

 

T1-ESF or E1-CRC4 modes

 

 

 

 

 

 

 

 

ES

Errored

 

For E1/T1: Any second containing the following error events:

 

 

 

Second (If any

CRC

 

 

 

error occurs

 

 

 

 

 

 

 

 

during one

 

SEF (OOF)

 

 

 

second)

 

AIS (T1 only)

 

 

 

 

 

 

 

 

 

 

If SES is also active (see below) ES runs for 10 seconds and then stops

 

 

 

 

 

 

 

 

SES

Severely

 

Any second containing the following errored events is counted as severely

 

 

 

Errored

 

errored seconds:

 

 

 

Seconds

 

For E1/T1:

 

 

 

 

 

 

 

 

 

 

If 320 or more CRC error events

 

 

 

 

 

One or more SEF (OOF) events

 

 

 

 

 

One or more AIS events occurred (for T1 only)

 

 

 

 

 

 

 

 

UAS

Unavailable

 

Activated when there are 10 consecutive SES occurrences and deactivated

 

 

 

Seconds

 

as a result of 10 consecutive seconds without SES

 

 

 

 

 

 

 

 

LOMF

Loss of

 

Loss Of Framing sequence in Timeslot 16

 

 

 

Framing

 

E1 CAS mode only

 

 

 

 

 

 

 

Table E-28lists the parameters can be monitored from the Link Status menu.

 

 

 

 

 

 

Table E-28. Link Status Parameters

 

 

 

 

 

 

 

Parameter

 

Description

 

 

 

 

 

 

 

Valid Intervals

 

Number of 15-minute intervals stored in the system since power-up

 

 

 

 

 

 

 

Time Since

 

Elapsed time since the beginning of the current interval

 

 

 

 

(interval 0). This is displayed only when the current interval is monitored.

 

 

 

 

 

 

 

Interval Number

 

Number of the interval to be displayed

 

 

 

 

Interval number 0 (zero) is the current interval. The current interval display is

 

 

 

 

continuously updated. The elapsed time since the beginning of the interval is

 

 

 

 

displayed.

 

 

 

 

 

 

 

Start Time

 

Time and date when the monitored interval started

 

 

 

 

Displayed only when viewing previous intervals.

 

 

 

 

 

 

 

Prev

 

Displays the previous interval

 

 

 

 

From the first interval (current interval = 0) Prev is not visible.

 

 

 

 

 

 

 

Next

 

Displays the next interval

 

 

 

 

The number of valid intervals is displayed. From the last valid interval Next is not

 

 

 

 

visible.

 

 

 

 

 

 

 

 

 

 

Performance Monitoring

E-43

Page 186