Cisco Systems IPMUX-1E operation manual Number of Ports, Compliance 168, Ms tail support

Models: IPMUX-1 IPMUX-1E

1 217
Download 217 pages 12.67 Kb
Page 64
Image 64

IPmux-1/1EInstallation and Operation Manual

Chapter 1 Introduction

 

 

 

 

Interfaces

FXS: Loop start for direct connection to a 2-wire

 

 

telephone

 

 

Nominal level: 0 dBm

 

 

Nominal impedance: 600

 

 

Return loss (ERL): Better than 20 dB

 

 

Frequency response: (Ref: 1020 Hz)

 

 

• ±0.5 dB, 300 TO 3000 Hz

 

 

• ±1.1 dB, 250 to 3400 Hz

 

 

Signal to total distortion, G.712, G.713 method 2:

 

 

0 to -30 dBm0, better than 33 dB

 

 

+3 to -45 dBm0, better than 22 dB

 

 

Idle channel noise: Better than -70 dBm0 (+20 dBrnc)

 

 

Transformer isolation: 1500 VRMS

 

 

Ringing - 22 Hz, sine wave

 

Diagnostics

Remote analog loopback towards the remote side,

 

 

activated from local side

 

 

1kHz tone injection towards analog side Activity indicators

ISDN S0

Number of Ports

4

Interface

 

 

 

Compliance

ETS 300012, I.430, NTT, 5ESS, DMS-100, NI1

 

Bit Rate

192 kbps

 

Line Coding

Pseudo-ternary

 

Line Termination

100Ω ± 5%

 

Connector

RJ-45

Echo

Compliance

G.168

Canceller

 

8 ms tail support

External Clock

 

 

E1

Compliance

ITUa-T Rec. G.703, G.706, G.732, G.823

 

Connector

Balanced: RJ-45 8-pin

 

 

Unbalanced: TBNC 75(an external adapter cable from

 

 

TBNC to BNC is required)

 

Data Rate

2.048 Mbps

 

Line Code

HDB3

 

Line Impedance

Balanced: 120; Unbalanced: 75

Technical Specifications

1-35

Page 64
Image 64
Cisco Systems IPMUX-1E Number of Ports, Compliance 168, Ms tail support, Line Impedance Balanced 120Ω Unbalanced 75Ω