Chapter 4 Troubleshooting and DiagnosticsIPmux-1/1EInstallation and Operation Manual

Table 4-1. Event Types

Event

Description

Corrective Action

 

 

 

COLD START

IPmux-1/1E has been powered up

None

 

 

 

CON LOCAL FAIL

Ethernet frames are not received by the

Check Eth/IP path

 

local IPmux-1 on the specified

 

 

connection

 

 

 

 

CON REMOTE FAIL

Ethernet frames are not received by the

Check Eth/IP path

 

remote IPmux-1 on the specified

 

 

connection

 

 

 

 

CON STANDBY

Redundancy bundle connection is not

None

 

the active connection (only applies

 

 

when redundancy is used)

 

 

 

 

CON TDM FAIL

LOS/LOF on the TDM line forced

Check the TDM line

 

redundancy switching (only applies

 

 

when redundancy is used)

 

 

 

 

CON SYNC

Bundle connection failure has ended

None

 

(only applicable when OAM is Enabled)

 

 

 

 

CON UNAVAILABLE

Remote IPmux is not available (only

Check the connection of the remote IPmux

 

applicable when OAM is Enabled)

 

 

 

 

CON VALIDATION FAIL

Connection is invalid (only applicable

Check the bundle parameters

 

when OAM is Enabled)

 

 

 

 

FATAL ERROR

IPmux-1/1E has encountered an

The IPmux-1/1E requires servicing

 

internal fatal error

 

 

 

 

IP ADDRESS IS ASSIGNED BY

Host IP has been learned by the DHCP

None

SERVER

protocol

 

 

 

 

IP ADDRESS IS RELEASED

Host IP has been relesased by the

Check the connection with the DHCP server

 

DHCP protocol

 

 

 

 

JIT BUF OFLOWS END

*Jitter Buffer Overflows END

Refer to Bundle Configuration Statistics in

BUNDLE 1

 

Appendix E

 

 

 

JIT BUF OFLOWS START

*Jitter Buffer Overflows START

Refer to Bundle Configuration Statistics in

BUNDLE 1

 

Appendix E

 

 

 

JIT BUF UFLOWS END

*Jitter Buffer Underflows END

Refer to Bundle Configuration Statistics in

BUNDLE 1

 

Appendix E

 

 

 

JIT BUF UFLOWS START

*Jitter Buffer Underflows START

Refer to Bundle Configuration Statistics in

BUNDLE 1

 

Appendix E

 

 

 

LINE AIS END

Line AIS state detected has ended

None

 

 

 

LINE AIS START

IPmux-1 has AIS (alarm indicator signal)

Check for a fault at the PDH network, on the

 

state on its E1/T1 port

receive direction

 

 

 

LINE FEBE END

LINE FEBE state detected has ended

None

 

 

 

LINE FEBE START

IPmux-1 has LINE FEBE state on its

Check for errors in the E1/T1 connection on

 

E1/T1 port

the transmit direction

 

 

 

LINE RDI END

LINE RDI state detected has ended

None

 

 

 

LINE RDI START

IPmux-1 has LINE RDI (remote defect

Check for a fault at the E1/T1 connectivity

 

indicator) state on its E1/T1 port

on the transmit direction

 

 

 

4-2

Error Detection

Page 99
Image 99
Cisco Systems IPMUX-1E operation manual Event Types, Event Description Corrective Action