IPmux-1/1E Installation and Operation Manual Appendix E Configuration Menus
Connection Configuration: Static Mode E-31
Protection Switching Configuration
PROTECTION SWITCHING CONFIGURATION
1. Primary Bundle ID Empty!
2. Secondary Bundle ID Empty!
3. Redundancy Type Empty!
4. TDM Fail Time Empty!
5. Event Threshold Window (sec) Empty!
6. Sequence Number Threshold (0=Disable) Empty!
7. Underflow/Overflow Threshold (0=Disable) Empty!
8. Local Fail Time (msec) Empty!
9. Force Connection Empty!
A. Recovery Empty!
B. Wait-To-Restore Time (sec) Empty!
ESC. Exit

Figure E-33. Protection Switching Configuration Menu

Table E-21. Protection Switching Configuration Parameters

Parameter Possible Values Remarks
Primary Bundle ID 1, None
Secondary Bundle ID 1, 2, None
Redundancy Type 1+1
1:1
Only one bundle is transmit
Both bundles are transmit
Note: For 1:1, OAM Connectivity must be enabled in
the Bundle Configuration menu.
TDM Fail Time Disable, Immediate,
100 msec to 1 sec
Event Threshold Window 1 to 1000 Relevaqnt for Sequence Number Threshold and
Underflow/Overflow Threshold.
Sequence Number
Threshold
1 to 1000 Redundancy will flip when this amount of sequence
numbers is exceeded within the threshold window
Underflow/Overflow
Threshold
1 to 1000 Redundancy will flip when this amount of
underflow/overflow events is exceeded within the
threshold window
Local Fail Time 2 to 1000 Redundancy will flip when the period is exceeded