Appendix E Configuration MenusIPmux-1/1EInstallation and Operation Manual

Table E-3. Authentication/Community Parameters

Parameter

Possible Values

Remarks

 

 

 

Authentication

On

On – an authentication-failure trap is generated

Failure Trap

Off

when a system manager attempts to set a

 

parameter within IPmux-1/1E with an incorrect

 

 

 

 

community value

 

 

 

Trap

Up to 10 alphanumeric characters

The entry is case-sensitive

 

 

 

Read

Up to 10 alphanumeric characters

The entry is case-sensitive

 

 

 

Write

Up to 10 alphanumeric characters

The entry is case-sensitive

 

 

 

Manager List

Main Menu

2. Configuration

1.General Configuration

2.Management Configuration

2.Manager List

The Manager List window parameters are used when IPmux-1 inband management capability is used. The parameters define the parameters for up to eight managers. These parameters are:

Manager IP address

Host index

In addition, the Manager List window parameters configure the traps to be received by a manager. The default for all traps is Off.

To access additional manager-list parameters:

Press <N> to go to the next Manager List window.

 

 

MANAGER LIST

1.

Manager IP Address

192.333.234.172

2.

Link Up/Down Trap

On

3.

Alarm Trap

On

5.

VLAN Tagging

 

6.

VLAN ID

 

7.

VLAN Priority

 

ESC. ExitS. SaveN. Next

Select item from the menu.

Use <Esc> key or keys <1> to <3>

Figure E-14. Manager List Menu

E-10 General Configuration

Page 153
Image 153
Cisco Systems IPMUX-1E operation manual Manager List, Table E-3. Authentication/Community Parameters, Off