Chapter 3 Site Preparation

Power and Grounding

Figure 3-3 Mixed Grounding System

 

 

 

 

 

 

 

 

 

 

 

Non-isolated equipment

 

 

48V-A

 

 

48V-A

T

48V-A

logic power

 

 

Z1

 

48V-A RTN

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety Ground

 

 

 

 

+

 

Z2

48V-B

T

 

 

 

 

 

 

 

48V-B

 

 

Battery A

 

Z1

48V-B RTN

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

Safety Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Z2

 

 

 

1

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

Z3

 

 

 

 

 

 

Z2

 

3

 

 

 

Z5

 

 

 

 

 

 

 

 

 

 

Z1

 

 

 

 

 

 

 

 

 

 

 

 

Isolated equipment

 

 

48V-B

 

 

48V-A

T

48V-A

logic power

 

 

 

 

48V-A RTN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety Ground

 

 

 

 

+

 

 

48V-B

T

 

 

 

 

 

 

 

48V-B

 

 

Battery B

 

Z1

48V-B RTN

 

 

 

 

 

 

2

 

 

 

 

 

Safety Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Z2

 

 

 

2

28311

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

Z4

 

 

 

 

 

 

 

 

4

 

 

 

 

Table 3-1 Ground Point Descriptions for Mixed Grounding

Connection

Description

 

 

Z1

–48 VDC return.

 

 

Z2

Protective earth or safety ground (green/yellow).

 

 

Z3

Equipment ground for non isolated equipment.

 

 

Z4

Equipment ground for isolated equipment.

 

 

Z5

Equalizing frame ground. This ground creates low-impedance equalization

 

between frames.

 

 

B

Battery ground.

 

 

1, 2, 3, 4

Connection points to the building’s ground system: a potential can exist between

 

these points within the ground system.

 

 

T

Common-mode EMI filters.

 

 

Cisco MGX 8230 Edge Concentrator Installation and Configuration

 

Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001

3-19

 

 

 

Page 127
Image 127