2-47
Cisco MGX 8230 Edge Concentrator Installation and Configuration
Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001
Chapter2 Module and Service Descriptions Frame Relay Service Modules
STBY LED (Standby) Yellow Slow blink without the A ct ive LED indicates the car d
is in the boot state.
Fast blink with the Standby L E D in d ica tes the card is
being downloaded.
Fast blink indicates the service module is passing
BRAM channel informatio n to th e P X M 1
Steady yellow indicates the card is in Standby mode
and the firmware is executing ADMIN co d e.
FAIL LED Red Steady Red w it h A ctive a nd S t an dby LE Ds off
indicates either the card is in the Reset condition, the
card has failed, or the card set is not complete (no line
module).
Steady Red with Active LED on i ndicates the card was
active prior to failing.
Steady Red with Standby LED on indicates the card
was standby prior to failing.
Both standby and red LED lit indicates self-test fa ilure.
Table2-13 LED Indicators for Eight-Port CESM (continued)
Type of LED Color Meaning