Chapter 6 Card and Service Configuration

Configuring Frame Relay Service

Step 6 Configure resources for the port as needed by executing cnfportrscprtn. To see the partitioning, use dspportrscprtn. The description has a high- and low-bandwidth version:

cnfportrscprtn <port_num> <controller> <percent BW> <low DLCI> <high DLCI> <max LCN>

For serial FRSM cards:

port_num is the port number in the range 1–2 for MGX-FRSM-2T3E3 and MGX-FRSM-HS2, 1–4 for MGX-FRSM-HS1/B, or 1–256 for MGX-FRSM-2CT3.

controller is a number representing the controller: 1=PAR, 2=PNNI, and 3=Tag.

percent BW is the percentage of the bandwidth in the range 0–100 and applies to both egress and ingress.

low DLCI is in the range 0–1023.

high DLCI is in the range 0–1023.

max LCN is the maximum number of logical connections available to the controller on this port. The ranges are 1–4000 for MGX-FRSM-2CT3, and 1–2000 for MGX-FRSM-2T3E3 and MGX-FRSM-HS2.

For AX-FRSM-8T1 or AX-FRSM-8E1:

port_num is the logical port number in the range 1–192 for T1 or 1–248 for E1.

controller-nameis PAR, PNNI, or TAG.

percent BW is the percentage of the bandwidth in the range 0–100 and applies to both egress and ingress.

low DLCI is in the range 0–1023.

high DLCI is in the range 0–1023.

max LCN is the maximum number of logical connections available to the controller on this port. The range is 1–1000.

Note The following step applies to Y-cable redundancy for the MGX-FRSM-2T3E3. For 1:N redundancy on the eight-port FRSMs, refer to “Redundancy Support by the MGX-SRM-3T3/C.”

Adding a Frame Relay Connection

This section describes how to add a Frame Relay connection according to the rules for adding a standard connection or a management connection in the form of either a DAX con or a three-segment connection. See “Rules for Adding Connections” earlier in this chapter.

Step 1 Add a connection by using addcon. If the application requires the NSAP form for the endpoint, use addchan as described in the command reference.

The system automatically assigns the next available channel number, so the addcon command does not require it. However, some related commands require a channel number. To see the channel number after you add a connection, use dspcons.

On the FRSM-VHS cards (2CT3, 2T3E3, or HS2):

 

 

Cisco MGX 8230 Edge Concentrator Installation and Configuration

 

 

 

 

 

 

 

Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001

 

 

6-31

 

 

 

 

 

Page 199
Image 199
Cisco Systems MGX 8230 manual Adding a Frame Relay Connection