Chapter 6 Card and Service Configuration

Configuring Frame Relay Service

addcon <port> <DLCI> <cir> <chan_type> <egress_service_type> [CAC] <controller_type> <mastership> [connID] <controllerID>

port is the logical port number on the MGX-FRSM-2CT3 in the range 1–256. On the MGX-FRSM-2T3E3 and MGX-FRSM-HS2, the range is 1–2. (See addport step if necessary.)

DLCI is the DLCI number in the range 0–1023 (2CT3/2T3/2E3/HS2).

cir is the committed information rate in one of the following ranges:

for 2CT3, 1–1536000 bps; for 2T3, 1–44210000 bps; 2E3, 1–34010000 bps; and for HS2, 1–51840000 bps.

chan_type specifies the type of connection: 1=NIW; 2=SIW-transparent mode; 3=SIW with translation; 4=FUNI; and 5=frame forwarding.

egress_service_type is a number that specifies the type of queue on the egress: 1=high priority; 2=real-time VBR, 3=nonreal-time VBR; 4=ABR; and 5=UBR.

CAC optionally enables connection admission control: 1=enable; 2=disable (default). With CAC enabled, the system adds the resource consumption represented by adding the connection to the total resources consumed on a logical port.

controller_type is the controller type for signaling connections: 1 (the default) specifies a PVC and applies to PAR; 2 specifies a SPVC and applies to PNNI.

mastership indicates if this end of the connection is master or slave: 1=master, 2=slave.

connID is the connection identifier at the remote end. It appears in the syntax as an optional parameter because it is mandatory only when you add the connection at the master end. See “Rules for Adding Connections” at the beginning of this chapter. connID can have one the following formats according to the slave endpoint:

Nodename.SlotNo.PortNo.DLCI

Nodename.SlotNo.PortNo.ControllerId.DLCI

Nodename.SlotNo.PortNo.VPI.VCI for ATM endpoint

controllerID is a number indicating the type of network control application: 1=PAR, 2=PNNI, 3=MPLS.

For AX-FRSM-8T1 and AX-FRSM-8E1:

addcon <port> <DLCI> <cir> <chan_type> [CAC] <controller_type> <mastership> <remoteConnID> <serv_type>

port is the logical port number in the range 1–192 for T1 or 1–248 for E1. (See addport step if necessary.)

DLCI is the DLCI number in the range 0–1023.

cir is the committed information rate in one of the following ranges: for T1, 0–1536000 bps for T1; for E1, 0–2048000 bps.

chan_type specifies the type of connection: 1=NIW; 2=SIW-transparent mode; 3=SIW with translation; 4=FUNI; and 5=frame forwarding.

CAC optionally enables connection admission control: 1=enable; 2=disable (default).

controller_type is the controller type for signaling: 1=PVC (PAR), the default, 2=SPVC (PNNI).

mastership indicates if this end of the connection is master or slave: 1=master, 2=slave.

 