Cisco Systems MGX 8230 manual T3 Trunk Cabling, Cable Parameter Description, Connector Description

Models: MGX 8230

1 282
Download 282 pages 49.23 Kb
Page 263
Image 263

A P P E N D I X B

Cable Specifications

This appendix contains details on the MGX 8230 cabling. It includes the following sections:

T3 Trunk Cabling

Frame Relay Cabling

DC Power Cabling

AC Power Cabling

Control and Clock Cabling

External Alarm Cabling

Note In all cable references, the transmit direction is away from the MGX 8230, and the receive direction is toward the MGX 8230.

T3 Trunk Cabling

A trunk cable connects each T3 port on the BNC-2T3 back card to a T3 port on other equipment. See Table B-1and Table B-2for details.

Table B-1 Trunk Cables

 

 

Cable Parameter

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

75-ohm coax cable (RG-59 B/U for short runs, AT&T 734A for longer runs).

 

 

 

 

Two per T3 line (XMT and RCV).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. Length

 

450 feet maximum between the MGX 8230 and other equipment.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connector

 

Terminated in male BNC; Rx is received from trunk, Tx is transmitted to

 

 

 

 

 

 

 

 

trunk.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table B-2 T3 Connector Pin Assignments

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connector

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rx BNC

Receive T3 from trunk

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tx BNC

Transmit T3 to trunk

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cisco MGX 8230 Edge Concentrator Installation and Configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001

 

B-1

 

 

 

 

Page 263