Appendix A Technical Specifications

MGX 8230 Enclosure, Power, and Performance Specifications

Table A-1 Enclosure and Electrical Characteristics

 

 

 

 

Item

Value

 

 

 

 

 

 

 

 

 

 

 

 

Card Slot Capacity

Supports combinations of full and single-height service modules.

 

 

 

 

 

Two double-height slots reserved for PXMs.

 

 

 

 

 

Up to 10 single-height slots for service modules or

 

 

 

 

 

up to 5 double-height slots for service modules.

 

 

 

 

 

 

 

 

 

 

 

 

Enclosure Size,

 

 

 

 

 

 

 

AC-powered system

8 Rack Units high

 

 

 

 

 

Height: 14.00 inches (35.56 cm).

 

 

 

 

 

Width: 17.72 ins (45.01 cm).

 

 

 

 

 

Depth: 23.5 ins (59.69 cm) (excluding cable management)

 

 

 

 

DC-powered system

7 Rack Units high

 

 

 

 

 

Height: 12.25 inches (63.50 cm).

 

 

 

 

 

Width: 17.72 inches (45.01 cm).

 

 

 

 

 

Depth: 23.5 inches (59.69 cm) (excluding cable management)

 

 

 

 

 

 

 

 

 

 

 

Shipping Weight for

Approximately 150 lbs.

 

 

 

 

Populated Enclosure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clearance Requirement

Minimum 30 inches front and rear; nominal 12-inch side clearance.

 

 

 

 

 

 

 

 

 

 

 

Power Input Voltage

AC system: Normal operating range is 100–240 VAC, 47 to 63 Hz.

 

 

 

 

 

The maximum voltage range is 90–264 VAC.

 

 

 

 

 

DC system: –42 to –56 VDC.

 

 

 

 

 

Each AC supply can provide up to 1200 Watts at –48 VDC.

 

 

 

 

 

 

 

 

 

 

 

Current Requirements,

Configuration-dependent: use Network Design Tool for exact

 

 

 

 

AC System

requirements.

 

 

 

 

 

 

 

 

 

 

 

Current Requirements,

Configuration-dependent: use Network Design Tool for exact

 

 

 

 

DC System

requirements. For general planning purposes: 25 Amps at nominal –48

 

 

 

 

 

VDC; 29 Amps at –42 VDC maximum.

 

 

 

 

 

 

 

 

 

 

 

Input AC Power

IEC 320 C13 input connector. The Appendix titled “Cabling

 

 

 

 

Connector

Specifications” lists the AC power cords for a variety of countries and

 

 

 

 

 

regions.

 

 

 

 

 

 

 

 

 

 

 

AC Power Cable

Provided with 8 feet (2.3 m) of 3-conductor wire with plug.

 

 

 

 

 

 

 

 

 

 

 

AC Plug at

20 A NEMA L620, 3-prong plug (domestic U.S.)

 

 

 

 

Customer end

13 A 250 Vac BS1363, 3-prong fused plug (UK, Ireland)

 

 

 

 

 

CEE 7/7 (Continental Europe)

 

 

 

 

 

AS3112 (Australia/New Zealand)

 

 

 

 

 

CEI23-16/VII (Italy)

 

 

 

 

 

125V/15A North America

 

 

 

 

 

 

 

 

 

 

 

DC Input Connections

Three-position terminal block for 10 AWG wire (4 square millimeters).

 

 

 

 

 

 

 

 

 

 

 

Operating Environment

0° –40°C (32° –104°F) normal operation (50° C or 122° F up to 72 hours).

 

 

 

 

 

Maximum 85% relative humidity.

 

 

 

 

 

 

 

 

 

 

 

Shock

Withstands 10 G, 10 ms at 1/2 sine wave.

 

 

 

 

 

 

 

 

 

 

 

Vibration

Withstands 1/4 G, 20–500 Hz.

 

 

 

 

 

 

 

 

 

 

 

Heat Transfer to

AC-powered: 4,800 BTUs.

 

 

 

 

Environment

DC-powered: 4,100 BTUs.

 

 

 

 

 

 

 

 

 

 

Cisco MGX 8230 Edge Concentrator Installation and Configuration

 

 

 

 

 

 

 

 

 

 

 

 

A-2

 

 

 

Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001

 

 

 

 

 

 

Page 234
Image 234
Cisco Systems MGX 8230 manual Value