Cisco Systems MGX 8230 manual Downloading Firmware to a Service Module, $tftp IP address, Then

Models: MGX 8230

1 282
Download 282 pages 49.23 Kb
Page 161
Image 161

Chapter 5 Configuring the MGX 8230 Shelf

MGX 8230 MGX to BPX Feeder

Note Stratum 3 clocking is available only with the PXM-UI-S3 back card. Stratum 4 clocking is available only with internal clock sources or with the PXM-UI back card.

Downloading Firmware to a Service Module

This section describes how to download firmware for a service module from a workstation. The descriptions apply whether you are upgrading the existing firmware or downloading because no runtime firmware resides on the hard drive.

Service modules do not retain runtime firmware. The hard drive on the MGX 8230 PXM may come with default firmware for the service modules, but the details of the customer order actually determine whether firmware is on the disk. If default firmware exists on the hard drive, the MGX 8230 PXM downloads it upon power-up or when you reset the card, otherwise you can download firmware from the workstation according to the instructions that follow.

Note that if you download firmware from a workstation to the hard drive, the MGX 8230 PXM does not automatically load the firmware to the card. You must reset the card (resetcd on the CLI) to download firmware from disk to the card. With the single execution of a command, you can load either generic firmware for all cards of a certain type or firmware destined to a specific slot.

To load service module firmware from a workstation to the hard drive on the MGX 8230 PXM:

Step 1 Start the tftp application:

$tftp <IP address>

then

>bin

Step 2 To download generic firmware for a type of service module to the MGX 8230 PXM hard drive:

>put cardtype.fw POPEYE@SM_1_0.FW

where cardtype is the firmware for a type of card; the shelf number always is 1; and the 0 represents the slot number for the purpose of generic download. An example of cardtype.fw is “frsm8t1e1_10.0.11.fw.” Note the space between “.fw” and “POPEYE.”

Step 3 To load slot-specific firmware at a particular card:

>put cardtype.fw POPEYE@SM_1_slot.FW

where cardtype is the firmware, and slot is the number of the card slot. Note the space between “.fw” and “POPEYE.” Repeat this step for each slot as needed.

Note Slot-specific firmware overwrites the current firmware at a slot.

With slot-specific firmware, the card does not come up if you do either of the following:

Specify the wrong firmware, where the firmware specified by cardtype does not match the targeted card at slot.

Insert a different card (which does not use the firmware specified for the slot).

 

 

Cisco MGX 8230 Edge Concentrator Installation and Configuration

 

 

 

 

 

 

 

Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001

 

 

5-9

 

 

 

 

 