6-22
Cisco MGX 8230 Edge Concentrator Installation and Configuration
Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001
Chapter6 Card and Service Configuration
ATM Universal Service Module (AUSM)
Step 5 If necessary, change the queue depths by using cnfchanq.
cnfchanq <port.vpi.vci> <discard_option> <vc_q_depth> <clp_thresh_high> <clp_thresh_low |
epd_threshold> <efci_thresh>
Variable Description Value range Default value
Chan_Num
ABRType ABRType 1 (Switch Behavior) and 2 (Source Destinat ion
Behavior). 1 (Switch
Behavior)
mcr Minimum Rate Valid value range from 10 to 38328 (includes
RM cell and Data cell band w id th ). Derived from
PCR(0+1)
pcr Peak Rate Valid value range from 10 to 38328 (includes
RM cell and Data cell band w id th ). Derived from
PCR (0+1)
icr Initial Cell
Rate Valid value range from 10 to 38328 (includes
RM cell and Data cell band w id th ). Derived from
PCR (0+1)
rif Rate Increase
Factor Valid range from 1 to 32768 (power of 2) 64
rdf Rate Decrease
Factor Valid range from 1 to 32768 (power of 2) 16
nrm Inrate Cell
Count Valid value range from 2 to 256 (power of 2). 64
trm Time limit fo r
Frm Valid value range from 3 to 255 msec. 255 msec.
tbe Transient Buf
Exposure Valid value range from 0 to 16777215 cells. 16777215 cells
frtt Fixed Round
Trip Time Valid value range from 0 to 16700 msec. 0 msec.
adtf ACR Decrease
Time Factor Valid value range from 10 to 10230 msec. 500msec.
cdf Cutoff
Decrease
Factor
Valid value range from 0 to 64 (power of 2). 16