Chapter 2 Module and Service Descriptions

Service Resource Module

Module Requirements with Bulk Distribution and Redundancy

The use of bulk distribution affects the requirements for SRM and service module back cards:

With bulk distribution and 1:N redundancy support by way of the distribution bus, the service modules do not use back cards.

For just 1:N redundancy by way of the redundancy bus, the supported service modules must have back cards—including one special redundancy back card. E1 redundancy requires the AX-R-RJ48-8E or AX-R-SMB-8E1 line module, and T1 redundancy requires the R-RJ48-8T1 line module.

For bulk distribution, the T3 lines connect to an external multiplexer. The T1 lines on the other side of the multiplexer connect to the CPE. The SRM converts the received traffic from its T3 lines to T1 channels and sends the data to linked service modules. For instructions on linking T1 channels and card slots to the MGX-SRM-3T3/C, see Chapter 6, “Card and Service Configuration”

Installation Requirements for the MGX-SRM-3T3/C

The following are card-level characteristics that apply to any SRM installation:

Only MGX-SRM-3T3/C cards can be installed in slots 7 and 14.

No other service modules can be installed in slots 7 and 14. These slots do not have cell bus connections. The SRM modules use a local bus to communicate with the PXM.

The PXM1 in slot 1 controls the SRM in slot 7. The PXM1 in slot 2 controlsthe SRM in slot 14.

Either SRM in slot 7 or 14 can be active (depending on the active PXM1).

SRM Illustration and LED Indicators

Table 2-1and Table 2-2describe the SRM-3T3 LED faceplate indicators.

Table 2-1 LED Indicators for the SRM-3T3/C

Type of LED

Color

Meaning

 

 

 

ACTIVE (ACT) LED

Green

Indicates card set is in active mode.

 

 

 

STANDBY (STBY)

Yellow

Indicates card set is in standby mode.

LED

 

 

 

 

 

FAIL (FAIL) LED

Red

Indicates BNM-155 card set has failed or the line

 

 

module is missing.

 

 

 

Table 2-2 Line Redundancy LED Indicators for the SRM-3T3/C

 

 

 

Type of LED

Color

Meaning

 

 

 

(1:N RED) LED

Green

On indicates 1:N redundancy has been invoked.

 

 

Off indicates 1:N redundancy is not active.

 

 

 

BERT (BERT) LED

Green

On indicates BERT function is active.

 

 

 

 

 

Cisco MGX 8230 Edge Concentrator Installation and Configuration

 

 

 

 

 

 

 

Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001

 

 

2-13

 

 

 

 

 

Page 59