6-19
Cisco MGX 8230 Edge Concentrator Installation and Configuration
Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001
Chapter6 Card and Service Configuration ATM Universal Service Module (AUSM)
cnfupcvbr has the same syntax and parameters as cnfupcabr
cnfupcvbr or cnfupcabr <port.vpi.vci> <enable> <pcr[0+1]> <cdvt[0+1]> <scr> <scr_police> <mbs>
<IngPcUtil> <EgSrvRate> <EgPcUtil > <clp_tag>
•EgSrvRate is the egress service rat e. Without IMA, the range is as fo llows:
–
T1, 10–3622 cells per second
–
E1, 10–4528 cells per second
–
clear E1, 10–4830 cells per second
For IMA, multiply the li ne r a te by th e number of links.
•EgrPcUtil is the percent utilization on t he egr ess . Th e r an g e i s 1–127.
The default is 0.
•port.vpi.vci identifies the connection.
•enable is the enabled/disable for UPC: 1=Disable, 2=Enable.
•pcr is the peak cell rate. Withou t IM A , t he range is as follows:
–
T1, 10–3622 cells per second
–
E1, 10–4528 cells per second
–
clear E1, 10–4830 cells per se c on d
For IMA, multiply the line rate by the number of links.
•cdvt cdvt[0+1] is the cell del a y vari at io n to ler a n ce f or c ells with
CLP=[0+1]. The range is 1–250000 micro seconds.
•scr is the peak cell rate. Without IMA , t he range is as follows:
–
T1, 10–3622 cells per second
–
E1, 10–4528 cells per second
–
clear E1, 10–4830 cells per se c on d
For IMA, multiply the line rate by the number of links.
•scr_police specifies the type of scr policing: 1= CLP[0] cells,
2=CLP[0+1] cells, an d 3= no SCR policing.
•mbs is the maximum burst size: the range is 1–5000 cells.
•IngPcUtil is the percent utilization on the egress. The range is 1–127. The
default is 0.