Chapter 4 Enclosure Installation

Rack Mounting an MGX 8230

Step 3 Make sure that the building AC receptacle is properly grounded.

Step 4 Repeat steps 2 through 3 for the second AC Power Supply Module if appropriate.

Figure 4-12illustrates a MGX 8230 chassis with two AC Power Supply Modules connected to the MGX 8230 backplane.

Figure 4-13illustrates an MGX 8230 with one AC Power Supply Module connected to the MGX 8230 backplane. If only one AC Power Supply Module is used in your MGX 8230, make sure that there are blank faceplates covering the slots for the second AC Power Supply Module and the opening where the DC PEM would otherwise be installed.

In order for the AC power supply to function the enable switch must be in the “On” position, and the DC cable must be connected between the AC power supply connector and the MGX 8230 backplane. Proceed to the section “Install the Cable Manager,” which is followed by the section “Power up the MGX 8230.”

Note An AC power module will not power on if the DC cable is disconnected from the MGX 8230 backplane.

Figure 4-12 Rear View of MGX 8230 with Two Optional AC Power Supply Modules

23825

 

Cisco MGX 8230 Edge Concentrator Installation and Configuration

4-16

Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001

Page 148
Image 148
Cisco Systems MGX 8230 manual 23825