Chapter 5 Configuring the MGX 8230 Shelf

MGX 8230 MGX to BPX Feeder

Configuring Logical Interfaces for the Feeder

To configure logical, broadband interfaces on the physical interface:

Step 1 Select the MGX 8230 PXM by clicking on the faceplate of the card. An outline of the card lights up.

Step 2 Select “Configure” then “card” at the top of the MGX 8230 graphic. The Configure Card window appears with information on the current card.

Step 3 Click on the button next to the CATEGORY field, then select Broadband Interfaces. A matrix appears for configuring logical interfaces on the active lines. The maximum number of user-ports is 32.

Step 4 Select the Create button to add a logical interface. A text box appears that lets you enter:

A number in the range 1–32 for the new logical interface

The port number of the physical line to which you assign the logical interface

A percentage of the maximum bandwidth on the line for the new logical interface

A minimum VPI number for the new logical interface in the range 0–4095

A maximum VPI number for the new logical interface in the range 0–4095

Step 5 Type a value in each of the fields, then press the Apply button. The message “Addition of broadband interface is successful” appears, otherwise an error message appears. Example errors are entries out-of-range or values that conflict with existing configurations.

Note The Create window’s message of successful addition of an interface is accurate, but new interfaces do not appear in the Configure Broadband Interfaces per Card window until you close and reopen this window.

Step 6 If necessary, specify additional interfaces in the matrix. You can leave the Create box open and write over residual text or reopen this box later.

Step 7 Select the Cancel button at the bottom of the window to exit.

If you subsequently want to delete or change a logical interface:

Step 1 Open the Broadband Interfaces window.

Step 2 On the row for the targeted logical interface, move the cursor to the Status column and hold the left mouse button down on the current status. A small menu opens with “add, “del,” and “mod” choices.

Select “del” to delete the interface. or

Select “mod” to change a parameter.

Step 3 Select the Modify button at the bottom of the window. To see the result of any changes, close then reopen the Broadband Interfaces window.

 

 