6-63
Cisco MGX 8230 Edge Concentrator Installation and Configuration
Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001
Chapter6 Card and Service Configuration DS3 Loopback Test
Step 1 Select a node with PXM-T3 back c ar d.
Step 2 Disable the receive FEAC validation crit er ia by usi ng C LI co m m and, cnfln -ds3 <slot>.<port>
-rfeac 3.
Step 3 Using dspln -ds3 <slot>.<port>, check that the FEAC validation code is disabled and the line is n o t in
loopback.
Step 4 Put the HP cerjac tester in loopback mode by pressing the loopback up button.
Step 5 From the tester, send a pattern and verify that it is not received back on the tester.
Step 6 Check that dsplog does not show any errors or alarms log ged.
Pass Criteria:
Disabling the FEAC validation code put the line in no loop.
Anything transmitted from the t es t er is no t r e ceived ba ck o n th e t ester when FEAC codes are
disabled on the DS3 interface.
No errors logged on the console or the log.
Configure DS3 Loopback Co des from the Standby PXM1 Car d
To verify that DS3 loopback codes canno t be co nfigu r ed f rom th e s t an dby P X M - 1 c ar d :
Step 1 Select a node with redundant PXM-T3 cards.
Step 2 Log on to the standby card.
Step 3 Configure the line using cnfln -ds3 <slot>.<port> -felpbnum 30.
Step 4 Try to configure the transmit FEAC code to be dsx3SendNoCode by using CLI c ommand, cnfln -ds3
<slot>.<port> -tfeac 1.
Step 5 Check that CLI rejects the co m m a nd a nd fa il s to ac cep t it.
Step 6 dsplog shows logs an error or a alarm logged.
Step 7 On the tester (for example, HP cer ja c t es te r), check that the code for dsx3SendNoCode has not been
received.
Pass Criteria:
DS3 loopback codes c annot be invoked from the s t an dby card.
Receive FEAC Validation
Transmit FEAC Codes
MGX 8230 Switch
with T3 Interface
DTA Tester
(Digital
Transmission
Analyzer)
46087
Receive FEAC Validation
Transmit FEAC Codes
MGX 8230 Switch
with T3 Interface
DTA Tester
(Digital
Transmission
Analyzer)
46087