Chapter 3. Communications Operations of the BHT

3.4.2 Communications Parameters

In System Mode and user programs written in BHT-BASIC, you may set the communi- cations parameters listed below.

Communications Port

Optical interface

Direct-connect interface

 

 

 

Transmission Speed

2400, 9600, 19200, 38400,

300, 600, 1200, 2400, 4800, 9600,

 

57600, or 115200 bps

19200, 38400, 57600, or 115200 bps

 

 

 

Character Length

8 bits

7 or 8 bits

 

 

 

Vertical Parity

None

Odd, even, or none

 

 

 

Stop Bit Length

1 bit

1 or 2 bits

 

 

 

In System Mode

Refer to Chapter 2, Subsection 2.5.3, [4.5], "Setting the communications environ- ments."

In BHT-BASIC

To set the transmission speed, character length, vertical parity, and stop bit length (To set the transmission speed only for the optical interface), use the OPEN "COM:" statement in BHT-BASIC.

OPEN "COM: ... " Opens the interface port selected in System Mode.

OPEN "COM1: ... " Opens the optical interface port for data transmission, irrespective of the setting in System Mode.

OPEN "COM2: ... " Opens the direct-connect interface port for data trans- mission, irrespective of the setting in System Mode.

Note that it is impossible to open both the optical interface port and the direct-connect interface port concurrently.

Through the interface port opened by the OPEN "COM:" statement, the XFILE statement transmits a designated file.