Denso BHT-7500S, BHT-7500W user manual Abnormal termination of phase, Eot

Models: BHT-7500W BHT-7500S

1 217
Download 217 pages 50.9 Kb
Page 202
Image 202

Phase 3 with iterated EOT transmission due to no response or invalid response

If the sending station receives no response or any invalid response from the receiving station in response to an EOT sent, it iterates sending of an EOT at three- second intervals up to ten times.

If the sending station receives an ACK before sending an EOT ten times, it termi- nates the message transmission normally and releases the data link.

Sending

 

EOT

station

 

3 seconds

 

EOT

3 seconds

 

 

 

 

 

 

EOT

 

 

 

ACK

 

 

 

 

 

Normal

 

 

termination

 

 

 

 

 

Receiving station

Abnormal termination of phase 3

If the sending station receives no ACK from the receiving station within three seconds from the 10th EOT, it terminates the message transmission abnormally and releases the data link.

Sending

 

station

EOT (1)

3 seconds

 

EOT (2)

3 seconds

EOT (3)

3 seconds

EOT (10)

or more

 

Abnormal termination

Receiving station

182

Page 202
Image 202