(2)Communications protocol option screen

SET￿ PROTOCOL￿

￿

< CONNECTOR >￿

￿

1:SERIAL No. : ON OFF￿

￿

2:H.PARITY : ON OFF￿

￿

3:LINKUP TIME:￿

￿

None 30 60 90 120￿

￿

4:FIELD SPACE:￿

￿

Ignore Data￿

￿

￿

Selecting "2:PROTOCOL" on the SET CONNECTOR screen calls up the screen shown at left.

Highlighted is the current setting.

1

SERIAL No.:

Selects whether or not the

 

 

system will add serial num-

 

 

bers to data blocks.

2

H. PARITY:

Selects whether or not the

 

 

system will add a horizontal

 

 

parity.

3

LINKUP TIME:

Selects the timeout length (in

 

 

seconds) to be applied when

 

 

a link is to be established.

4

FIELD SPACE:

Selects whether space codes

 

 

in the tail of a data field will

 

 

be ignored or handled as

 

 

data.

Select a desired item by using the numerical keys

or and keys. Then select a desired setting

by using the and keys.

To return to the SET CONNECTOR screen, press the C key.

If the BHT-Ir protocol has been selected, the serial number and horizontal parity settings will be ignored.