Chapter 2. Getting Started the BHT and System Mode

Testing the optical interface port

TEST COMMUNICATION￿

￿

< OPTICAL >￿

￿

￿

1:SLAVE￿

￿

2:MASTER

Selecting the "1:OPTICAL" on the TEST COMMU- NICATION menu calls up the screen shown at left.

At the slave BHT to be tested, select the "1:SLAVE" and at the master BHT, select the "2:MASTER." Then press the ENT key on each BHT.

￿￿

TEST COMMUNICATION￿

￿

< OPTICAL >￿

￿

￿

￿

** Testing **

￿￿

TEST COMMUNICATION￿

￿

< OPTICAL >￿

￿

￿

￿

** Test NG **￿

￿

(XX)

￿￿

During the test, the screen shown at left is dis- played.

If any error occurs, the tested slave BHT beeps three times and shows the screen at left.

In parentheses are error codes which have the following meanings:

(X X)

1: The received data is different from the sent data.

2:A timeout has occurred during standby for data reception.

1:2400 bps

2:9600 bps

3:115200 bps

Press the C key to return to the TEST COMMUNI- CATION menu.

The master BHT will automatically return to the TEST COMMUNICATION menu after 10 seconds from the occurrence of an error.

79

Page 99
Image 99