Denso BHT-7500S, BHT-7500W user manual Communications parameters setting screen

Models: BHT-7500W BHT-7500S

1 217
Download 217 pages 50.9 Kb
Page 82
Image 82

(1)Communications parameters setting screen

SET￿ PARAMETER￿

￿

< OPTICAL >￿

￿

1:TRANSMIT SPEED:￿

￿

2400 9600 19200￿

38400 57600 115200

Selecting "1:PARAMETER" on the SET OPTICAL screen calls up the screen shown at left.

Highlighted is the current setting.

Select the desired transmission speed by using

the numerical keys or and keys, and then press the ENT key.

To return to the SET OPTICAL screen, press the C key.

(2)Communications protocol option screen

SET￿ PROTOCOL￿

￿

< OPTICAL >￿

￿

1:SERIAL No. : ON OFF￿

￿

2:H.PARITY : ON OFF￿

￿

3:LINKUP TIME:￿

￿

None 30 60 90 120￿

￿

4:FIELD SPACE:￿

￿

Ignore Data￿

￿

￿

Selecting "2: PROTOCOL" on the SET OPTICAL screen calls up the screen shown at left.

Highlighted is the current setting.

1

SERIAL No.:

Selects whether or not the

 

 

system will add serial num-

 

 

bers to data blocks.

2

H. PARITY:

Selects whether or not the

 

 

system will add a horizontal

 

 

parity.

3 LINKUP TIME: Selects the timeout length (in seconds) to be applied when a link is to be established.

4 FIELD SPACE: Selects whether space codes in the tail of a data field will be ignored or handled as data.

Select a desired item by using the numerical keys

or and keys. Then select a desired setting

by using the and keys.

To return to the SET OPTICAL screen, press the C key.

If the BHT-Ir protocol has been selected, the serial number and horizontal parity settings will be ignored.

62