Chapter 2. Getting Started the BHT and System Mode

[5.3] Beeper scale test

TEST BEEPER

￿￿

Selecting "3:BEEPER" on the TEST menu calls up the screen shown at left and makes the beeper sound at three octaves listed below.

Upon completion of this test, the BHT automati- cally returns to the TEST menu.

To stop this test while in progress, turn the power off and on.

Scale

 

Frequency (Hz)

 

 

 

 

 

 

do

523

1046

2093

4186

 

 

 

 

 

re

587

1174

2349

-

 

 

 

 

 

mi

659

1318

2637

-

 

 

 

 

 

fa

698

1396

2793

-

 

 

 

 

 

sol

783

1567

3135

-

 

 

 

 

 

la

880

1760

3520

-

 

 

 

 

 

ti

987

1975

3951

-

 

 

 

 

 

[5.4] Aging test

TEST AGING

DATE 00/03/01

TIME 15:30:00

Selecting "4:AGING" on the TEST menu proceeds to the aging test while showing the current date and time on the LCD. (This test is intended for personnel which check the BHT in the factory.)

Once this test is selected, the automatic pow- ering-off function becomes disabled. Be sure to turn the power off or press the C key to return to the TEST menu.

77

Page 97
Image 97
Denso BHT-7500W, BHT-7500S user manual Beeper scale test, Aging test