Phase 3 with timeout at the receiving station

If the receiving station receives no subsequent text or normal sequence of DLE EOT and IDs within 30 seconds after sending a sequence of DLE ACK and IDs, it sends a sequence of DLE EOT and IDs and aborts the transmission abnormally.

Sending station

Data text #n

DLE ACK and IDs

DLE EOT and IDs

Receiving station

30 seconds

Abnormal termination

[ 2 ] Aborting Data Transmission

Pressing the

C

key aborts data transmission.

If the C key is pressed during downloading, the BHT transmits a sequence of DLE EOT and IDs and aborts the file transmission.

If it is pressed during uploading, the BHT transmits the current transmission block followed by a sequence of DLE EOT and IDs and then aborts the file transmission.