Chapter 2. Getting Started the BHT and System Mode

[4.5-2] Setting the communications parameters for the direct-connect

interface

SET CONNECTOR￿

￿

￿

1:PARAMETER￿

￿

2:PROTOCOL

￿￿

Selecting "2:CONNECTOR" on the SET COMMUNI- CATION menu calls up the screen shown at left.

1

PARAMETER:

Switches to the commu-

 

 

nications parameters set-

 

 

ting screen.

2

PROTOCOL:

Switches to the commu-

 

 

nications protocol option

 

 

screen.

Select a desired screen by using the numerical

keys or and keys, and then press the ENT key.

To return to the SET COMMUNICATION menu, press the C key.

(1) Communications parameters setting screen

SET￿ PARAMETER￿

￿

< CONNECTOR >￿

￿

1:TRANSMIT SPEED:￿

￿

300600 1200￿

2400 4800 9600￿

19200 38400 57600￿ 115200￿

￿

2:PARITY BIT:￿

None Odd Even￿

￿

3:DATA BIT: 7bits 8bits￿

￿

4:STOP BIT: 1bit 2bits

Selecting "1:PARAMETER" on the SET CONNEC- TOR screen calls up the screen shown at left.

Highlighted is the current setting.

1

TRANSMIT SPEED:

Sets the

transmission

 

 

speed.

 

2

PARITY BIT:

Sets the

vertical parity:

 

 

none, odd, or even.

3

DATA BIT:

Sets the character length.

4

STOP BIT:

Sets the stop bit length.

Select a desired item by using the numerical keys

or and keys. Then select a desired setting

by using the and keys.

To return to the SET CONNECTOR screen, press the C key.

If the BHT-Ir protocol has been selected, the parity bit, character length, and stop bit length settings will be ignored.