Henny Penny Sure Chef Combi-Steamer models CSG-10/12/20, Control Panel Functions at a glance

Models: CSG

1 94
Download 94 pages 40.14 Kb
Page 15
Image 15
Sure Chef® Combi-Steamer models CSG-10/12/20

Control Panel Functions at a glance

Sure Chef® Combi-Steamer models CSG-10/12/20

1Warning light–lights red when cabinet temperature exceeds 239°F (115°C)

2NO WATER warning light (red)–check water supply

3ON indicator light (green)

4Digital COOKING/PROBE TEMPERATURE display–actual cabinet or internal food/probe temperature

5PROBE COOKING indicator display

6Mode selection switch (lighted display indicates the selected mode)

7STEAM mode–212°F (100°C)

For steaming, stewing, blanching, preserving, etc.

8CONVECTION mode–86°F to 575°F (30°C to 300°C)

For roasting, baking grilling, etc

9COMBINATION mode–86°F to 575°F (30°C to 300°C)

For Combi-Steaming instead of roasting and glazing or baking with moisture

Forced Steaming between 213°F to 266°F (101°C to 130°C)–firm vegetables or potatoes are cooked more quickly

10TENDER STEAMING mode–86°F to 210°F (30°C to 99°C)

For blanching, poaching, simmering, soaking, vacuum cooking

11RETHERMALIZING mode–86°F to 575°F (30°C to 300°C)

For reheating pre-cooked (chilled) food

12SELECTED TEMPERATURE display

13TEMPERATURE SELECTION dial

14COOKING TIME display

Shows actual cooking time remaining

15TIMER dial (0 to 120 minutes)

Select “CR” for Continuous Run

16PROBE pre-selected “DONE” TEMPERATURE display

17PROBE TEMPERATURE SELECTION dial

Select from 68°F to 210°F (20°C to 99°C)

Unit shuts off automatically when “done” temperature is reached

18Warning light–Steam burner malfunction

19Warning light–Convection burner malfunction

20Unit serial number

Please refer to this number when requesting service

14

Page 15
Image 15
Henny Penny manual Sure Chef Combi-Steamer models CSG-10/12/20, Control Panel Functions at a glance