Hitachi J300U Series instruction manual 12-10

Models: J300U Series

1 145
Download 145 pages 53.04 Kb
Page 101
Image 101

 

Display

(Function mode 1)

(Function mode 2)

 

Setting, change

 

 

 

Function

Function

Initialization display

Initialization

Setting contents

 

 

sequence

contents

 

 

No.

name

contents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

F-26

Frequency

LIMIT L

0000.0 Hz

0 Hz

0 to 120.0

The lower limit of the frequency

 

 

 

Frequency

lower limiter

 

 

 

(400) Hz

to be set is set. When the lower

 

 

 

limiter

setting

 

 

 

 

limit is 0, the setting is invalid.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

LIMIT H

0000.0 Hz

0 Hz

0 to 120.0

The upper limit of the frequency

 

 

 

 

upper

 

 

 

(400) Hz

to be set is set. When the upper

 

 

 

 

limiter

 

 

 

 

limit is 0, the setting is invalid.

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

F-27

Jump

JUMP F1

0000.0 Hz

0 Hz

0 to 400 Hz

• The section where frequencies

 

 

 

Jump

frequency

 

 

 

 

are to be jumped is set.

 

 

 

frequency

setting (1)

 

 

 

 

• Up to three locations can be

 

 

 

 

 

 

 

 

 

set.

 

 

 

 

 

 

 

 

 

• When the number of locations

 

 

 

 

 

 

 

 

 

is 0, the setting is invalid.

 

 

 

 

Jump

JUMP F2

0000.0 Hz

0 Hz

0 to 400 Hz

 

 

 

 

 

frequency

 

 

 

 

 

 

 

 

 

setting (2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Jump

JUMP F3

0000.0 Hz

0 Hz

0 to 400 Hz

 

 

 

 

 

frequency

 

 

 

 

 

 

 

 

 

setting (3)

 

 

 

 

 

 

 

 

 

Jump

JUMP W

0.5 Hz

0.5 Hz

0 to 9.9 Hz

• The frequency width where

 

 

 

 

frequency

 

 

 

 

frequencies are jumped is set.

 

 

 

 

width setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

F-28

STOP key

STOP-SW

ON

ON

ON: STOP key

Whether or not to make the

 

 

 

 

validity

 

 

 

valid

STOP key valid during terminal

 

 

 

 

selection

 

 

 

OFF: STOP key

running is selected. In the

 

 

 

 

during

 

 

 

invalid

Remote mode, the STOP key is

 

 

 

 

terminal

 

 

 

 

always valid.

 

 

 

 

running

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

F-29

Running

F/R SW

FRE

FRE

FWD/REV/

FWD: Only forward run

 

 

 

 

direction

 

 

 

FRE

REV: Only reverse run

 

 

 

 

selection

 

 

 

 

FRE: Both forward run and

 

 

 

 

 

 

 

 

 

reverse run valid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reverse run

F/R PREV

OFF

OFF

ON/OFF

Reverse run prevention

 

 

 

 

prevention

 

 

 

 

ON:

 

 

 

 

selection

 

 

 

 

OFF:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reduced

F/R RVS

6

6

0 to 6

 

 

 

 

 

voltage

 

 

 

 

 

 

 

 

 

soft start

 

 

 

 

 

 

 

 

 

setting

 

 

 

 

 

 

 

23

F-30

Maximum

F-MAX-L

120 Hz

120 Hz

120/400 Hz

Maximum frequency switching:

 

 

 

 

frequency

 

 

 

 

120: 120 Hz 400: 400 Hz

 

 

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

F-31

Analog input

IN ANA

10 V

10 V

10/5

Input voltage maximum level

 

 

 

External

voltage

 

 

 

 

10: Max. 10 V 5: Max. 5 V

 

 

 

analog

selection

 

 

 

 

 

 

 

 

frequency

External

IN EXS

0000.0 Hz

0 Hz

0 to 120.0 (400)

• Frequency at which the

 

 

 

command

frequency

 

 

 

 

external input starts

 

 

 

 

start setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External

IN EXE

0000.0 Hz

0 Hz

0 to 120.0 (400)

• Frequency at which the

 

 

 

 

frequency

 

 

 

 

external input is maximized

 

 

 

 

end setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External

IN EX%S

000%

0%

0 to 100

• Input start level

 

 

 

 

frequency

 

 

 

 

 

 

 

 

 

start setting

 

 

 

 

 

 

 

 

 

rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External fre-

IN EX%E

100%

100%

0 to 100

• Input maximum level

 

 

 

 

quency end

 

 

 

 

 

 

 

 

 

setting rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External

IN LEVEL

0 Hz

0 Hz

0 Hz/ExS

EXS: Start at EX%S setting

 

 

 

 

command

 

 

 

 

rate or less

 

 

 

 

start point

 

 

 

 

 

 

 

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12-10

Page 101
Image 101
Hitachi J300U Series instruction manual 12-10