Display

(Function mode 1)

(Function mode 2)

 

Setting, change

 

 

 

 

 

 

 

 

 

 

Function

Function

Initialization display

Initialization

 

Setting contents

sequence

contents

 

No.

name

contents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

F-08

Accelera-

Fsp F

 

0000.0 Hz

0 Hz

0 to 400.0

• The frequency at which the

 

Accelera-

tion stop

 

 

 

 

 

acceleration operation is

 

tion halt

frequency

 

 

 

 

 

stopped temporarily is set.

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accelera-

Fsp TIME

 

00.0 s

0 s

0 to 60.0

• The time that the acceleration

 

 

tion stop

 

 

 

 

 

is stopped temporarily at a

 

 

time setting

 

 

 

 

 

certain frequency during

 

 

 

 

 

 

 

 

acceleration is set.

 

 

 

 

 

 

 

 

 

10

F-09

Pattern

PARAM

 

REM

REM

REM/

• The parameter setting com-

 

 

command-

 

 

 

 

OP1/OP2

manding source is selected.

 

 

ing method

 

 

 

 

(Option

REM (each operator),

 

 

selection

 

 

 

 

connected)

OP1 (option 1), OP2 (option

 

 

 

 

 

 

 

 

2)

 

 

 

 

 

 

 

 

 

 

 

11

F-10

 

 

 

 

 

 

 

 

 

Running

 

 

 

 

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Running

RUN MODE

NOR

NOR

NOR/OEN/

NOR:

Normal running

 

 

mode

 

 

 

 

GOD

OEN:

Energy conservation

 

 

selection

 

 

 

 

 

 

running

 

 

 

 

 

 

 

 

GOD:

Fuzzy most suitable

 

 

 

 

 

 

 

 

 

acceleration and

 

 

 

 

 

 

 

 

 

deceleration running

 

 

 

 

 

 

 

 

 

 

 

 

Restarting

RUN FRS

 

ZST

ZST

fST/ZST

fST:

Restart after frequency

 

 

after FRS

 

 

 

 

 

 

maching

 

 

signal

 

 

 

 

 

ZST:

0 Hz start

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

F-11

Multistage

SPD 1

0000.00 Hz

0 Hz

0 to 120.0 (400)

• The input terminal CF1 is set

 

Multistage

speed

 

 

 

 

 

and used.

 

speed

1 speed

 

 

 

 

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multistage

SPD 2

0000.00 Hz

0 Hz

0 to 120.0 (400)

• The input terminal CF2 is set

 

 

speed

 

 

 

 

 

and used.

 

 

2-speed

 

 

 

 

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multistage

SPD 3

0000.00 Hz

0 Hz

0 to 120.0 (400)

• The input terminals CF1 and

 

 

speed

 

 

 

 

 

CF2 are set and used.

 

 

3-speed

 

 

 

 

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multistage

SPD 4

0000.00 Hz

0 Hz

0 to 120.0 (400)

• The input terminals CF1 and

 

 

speed

 

 

 

 

 

CF3 are set and used.

 

 

4-speed

 

 

 

 

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multistage

SPD 5

0000.00 Hz

0 Hz

0 to 120.0 (400)

• The input terminals CF2 and

 

 

speed

 

 

 

 

 

CF3 are set and used.

 

 

5-speed

 

 

 

 

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multistage

SPD 6

0000.00 Hz

0 Hz

0 to 120.0 (400)

• The input terminals CF1, CF2,

 

 

speed

 

 

 

 

 

and CF3 are set and used.

 

 

6-speed

 

 

 

 

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multistage

SPD 7

0000.00 Hz

0 Hz

0 to 120.0 (400)

• The input terminal CF3 is set

 

 

speed

 

 

 

 

 

and used.

 

 

7-speed

 

 

 

 

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12-7