Display

(Function mode 1)

(Function mode 2)

 

Setting, change

 

 

 

 

 

 

 

Function

Function

Initialization display

Initialization

Setting contents

sequence

contents

No.

name

contents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

F-05

Motor

AUX M

123.60 mH

Ratedcapacity

0 to 655.35

• Primary self inductance per

 

Motor

M setting

 

 

ofeachinverter

 

phase.

 

constant

constant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

AUX J

0.44 kgm2

Ratedcapacity

0 to 655.35

• Motor and machine inertia

 

 

J setting

 

 

ofeachinverter

 

 

 

 

constant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

AUX Kp

002.00

2.0

0 to 100.00

• Smaller: High response

 

 

constant

 

 

 

 

• Larger: Low response

 

 

Kp setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

AUX Ti

00100 ms

100 ms

0 to 10000

• Set this item after the

 

 

constant

 

 

 

 

feedback option PCB is

 

 

Ti setting

 

 

 

 

installed.

 

 

 

 

 

 

 

 

 

 

Motor

AUX KPP

001.00

1.0

0 to 100.00

• Set this item after the

 

 

constant

 

 

 

 

feedback option PCB is

 

 

KPP setting

 

 

 

 

installed.

 

 

 

 

 

 

 

 

7

F-06

Accelera-

ACC 1

0030.00 s

30.00 s

0.01 to 3000

• When the fuzzy most

 

Accelera-

tion time

 

 

 

 

suitable acceleration and

 

tion time

setting

 

 

 

 

deceleration (F-10) are set,

 

 

 

 

 

 

 

the time displayed here is

 

 

 

 

 

 

 

invalid, though it can be

 

 

 

 

 

 

 

set.

 

 

 

 

 

 

 

 

 

 

2-stage

ACC 2

0015.00 s

15.00 s

0.01 to 3000

• The acceleration time can

 

 

acceleration

 

 

 

 

be used when the input

 

 

time setting

 

 

 

 

terminal CH1 is shorted.

 

 

 

 

 

 

 

• For input terminal

 

 

 

 

 

 

 

selection, refer to F-34

 

 

 

 

 

 

 

input terminal.

 

 

 

 

 

 

 

 

 

 

Curve

ACC LINE

L

L

L (Linear),

• The curve pattern is set for

 

 

pattern

 

 

 

S (S curve),

acceleration and

 

 

selection

 

 

 

U (U curve),

deceleration respectively.

 

 

for

 

 

 

RU (reverse

 

 

 

acceleration

 

 

 

U curve)

 

 

 

 

 

 

 

 

 

 

 

Accelera-

ACC GAIN

02

2 (common to

1 to 10

• When the constant is set

 

 

tion and

 

 

acceleration

 

for one of acceleration and

 

 

deceleration

 

 

and

 

deceleration, it is common

 

 

curve

 

 

deceleration)

 

to both acceleration and

 

 

constant

 

 

 

 

deceleration.

 

 

selection

 

 

 

 

• See appendix 4.

 

 

 

 

 

 

 

 

8

F-07

Decelera-

DEC 1

0030.00 s

30.00 s

0.01 to 3000S

• When the fuzzy most

 

Decelera-

tion time

 

 

 

 

suitable acceleration and

 

tion time

setting

 

 

 

 

deceleration (F-10) are set,

 

 

 

 

 

 

 

the time displayed here is

 

 

 

 

 

 

 

invalid, though it can be

 

 

 

 

 

 

 

set.

 

 

 

 

 

 

 

 

 

 

2-stage

DEC 2

0015.00 s

15.00 s

0.01 to 3000S

• The deceleration time can

 

 

deceleration

 

 

 

 

be used when the input

 

 

time setting

 

 

 

 

terminal CH1 is shorted.

 

 

 

 

 

 

 

• For input terminal

 

 

 

 

 

 

 

selection, refer to F-34

 

 

 

 

 

 

 

input terminal.

 

 

 

 

 

 

 

 

 

 

Curve

DEC LINE

L

L

L (Linear),

• The curve pattern is set for

 

 

pattern

 

 

 

S (S curve),

acceleration and decelera-

 

 

selection

 

 

 

U (U curve),

tion respectively.

 

 

for

 

 

 

RU (reverse

 

 

 

deceleration

 

 

 

U curve)

 

 

 

 

 

 

 

 

 

 

 

Accelera-

DEC GAIN

02

2 (common to

1 to 10

• When the constant is set

 

 

tion and

 

 

acceleration

 

for one of acceleration and

 

 

deceleration

 

 

and decelera-

 

deceleration, it is common

 

 

curve

 

 

tion)

 

to both acceleration and

 

 

constant

 

 

 

 

deceleration.

 

 

selection

 

 

 

 

• See appendix 4.

12-6

Page 97
Image 97