12.3Function mode

Function mode list when the remote operator is used

• Function mode initial values and display contents

Initial display contents, initialization, and change ranges are displayed in the table indicated below.

Display

(Function mode 1)

(Function mode 2)

 

Setting, change

 

 

 

 

 

 

 

Function

Function

Initialization display

Initialization

Setting contents

sequence

contents

No.

name

contents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

F-00

Base

F-BASE

0060 Hz

60 Hz

30 to 120 (400)

• When 120 Hz is switched to

 

 

frequency

 

 

 

 

400 Hz by F-30, a frequency

 

 

setting

 

 

 

 

more than 120 Hz can be set.

 

 

 

 

 

 

 

 

2

F-01

Maximum

F-MAX

0060 Hz

60 Hz

30 to 120 (400)

 

 

 

frequency

 

 

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

3

F-02

Start

Fmin

0.50 Hz

0.5 Hz

0.1 to 9.9

• The equipment starts running

 

 

frequency

 

 

 

 

at this set value.

 

 

adjustment

 

 

 

 

 

 

 

 

 

 

 

 

 

4

F-03

Motor input

AVR AC

460 V

230/460

200,215,220,230

• The motor input voltage is set.

 

Input

voltage

 

 

 

/380,400,415

 

 

voltage

setting

 

 

 

440,460,480

 

 

 

 

 

 

 

 

 

 

 

AVR

AVRDEC

OFF

OFF

ON/OFF

• ON or OFF of the AVR

 

 

function

 

 

 

 

function for deceleration

 

 

for

 

 

 

 

is set. When dynamic

 

 

decelera-

 

 

 

 

braking torque is necessary

 

 

tion

 

 

 

 

for deceleration, OFF is set.

 

 

 

 

 

 

 

 

5

F-04

Control

CONTROL

VC

VC

VC, VP1, VP2,

• VC, VP1, VP2, VP3:

 

 

method

 

 

 

VP3, SLV, V2

V/F characteristics

 

 

setting

 

 

 

 

SLV:Sensorless vector control

 

 

 

 

 

 

 

V2:Sensor vector control

 

 

 

 

 

 

 

 

6

F-05

Autotuning

AUX AUTO

NOR

NOR

NOR/AUT/NRT

• At the first running after

 

 

Motor

setting

 

 

 

AUT/NRT is set, the

 

constant

 

 

 

 

 

autotuning measurement

 

(NOTE 1)

 

 

 

 

 

operation is executed.

 

 

 

 

 

 

 

 

 

 

Motor data

AUX DATA

NOR

NOR

NOR: Old Hitachi

• The autotuning motor data

 

 

selection

 

 

 

general purpose

before starting autotuning

 

 

 

 

 

 

TMO: New

measurement is data

 

 

 

 

 

 

Hitachi general

equivalent to NOR.

 

 

 

 

 

 

purpose

 

 

 

 

 

 

 

AUT: Auto-

 

 

 

 

 

 

 

tuning data

 

 

 

 

 

 

 

 

 

 

 

Motor

AUX K

005.50 kW

Ratedcapacity

3.7 to 160

• Set a capacity smaller than the

 

 

capacity

 

 

ofeachinverter

 

rated capacity as capacity

 

 

 

setting

 

 

 

data.

 

 

 

 

 

 

 

 

 

 

Motor pole

AUX P

4p

4p

2, 4, 6, 8

• The number of poles of the

 

 

count

 

 

 

 

motor to be used is set.

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

AUX R1

1.004

Ratedcapacity

0 to 65.535

 

 

 

constant

 

 

ofeachinverter

 

 

 

 

R1 setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

AUX R2

0.776

Ratedcapacity

0 to 65.535

 

 

 

constant

 

 

ofeachinverter

 

 

 

 

R2 setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

AUX L 13.16 mH

Ratedcapacity

0 to 655.35

 

 

 

constant

 

 

ofeachinverter

 

 

 

 

L setting

 

 

 

 

 

NOTE 1: The motor constants R1, R2, L, M, J, Kp, Ti, and KPP vary with the capacity.

12-5

Page 96
Image 96
Hitachi J300U Series instruction manual Function mode, 12-5