Monitor

mode contents

Contents and display

The product of the value of frequency converted value setting (A47) and that of output frequency (d0) is displayed on the monitor.

FUNC

(1)

 

 

.

to

.

0.0 to 9.99

 

 

(2)

FUNC

(3)

(4)

(5)

.

.

to

to

to

to

.

.

10.00to 99.99

100.00to 999.99

1000.00 to 9999.99

10000.00 to 39960.00

Frequency converted value monitor

Trip monitor

When a trip occurs, the cause of the trip is displayed in this code. As a general display,

the contents of the latest trip are displayed. Whenever the FUNC key is pressed, the content of each is displayed.

FUNC

FUNC

FUNC

Trip current

Voltage between trips

Trip cause

 

 

P and N

 

 

(Note 2)

NOTE 1: When there is no trip,

is displayed.

NOTE 2: The above example of the voltage between P(+) and N(-) indicates 390 to 399 V.

NOTE 3: When the STOP/RESET key is pressed after a trip occurs,

.

is displayed.

The causes of the last trip and the last trip but one are displayed. When the command is displayed and the FUNC key is pressed, the trip cause is displayed.

Trip history monitor

FUNC

FUNC

Cause of the last trip Cause of the last trip but one

FUNC

NOTE 1: When there is not a trip history,

is displayed.

NOTE 2: How to delete trip history data, see page 7-14.

7-8

Page 48
Image 48
Hitachi J300U Series instruction manual 10.00 to 100.00 to, Trip current, Trip cause, Is displayed