Display

(Function mode 1)

(Function mode 2)

 

Setting, change

 

 

 

 

 

 

 

Function

Function

Initialization display

Initialization

Setting contents

sequence

contents

No.

name

contents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

IN F-SAMP

8

8

1 to 8

 

 

 

command

 

 

 

 

 

 

 

sampling

 

 

 

 

 

 

 

frequency

 

 

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

25

F-32

Arrival

ARV PTN

CST

CST

CST/PAT/ANY

CST: Output at constant

 

Frequency

signal output

 

 

 

 

frequency arrival

 

arrival

pattern

 

 

 

 

PAT: Output of more than

 

output

selection

 

 

 

 

set frequency

 

signal

 

 

 

 

 

ANY: Output of only set

 

 

 

 

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

Arrival

ARV ACC

0.0 Hz

0 Hz

0 to 400.0

 

 

 

frequency

 

 

 

 

 

 

 

rate setting

 

 

 

 

 

 

 

for

 

 

 

 

 

 

 

acceleration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Arrival

ARV DEC

0.0 Hz

0 Hz

0 to 400.0

 

 

 

frequency

 

 

 

 

 

 

 

rate setting

 

 

 

 

 

 

 

for

 

 

 

 

 

 

 

deceleration

 

 

 

 

 

 

 

 

 

 

 

 

 

26

F-33

Overtorque

OV-TRQ V

100%

100%

0 to 250

• During control of SLV

 

Over-

signal rate

 

 

 

 

and V2: Power running

 

torque

setting

 

 

 

 

overtorque level

 

signal

(for power

 

 

 

 

• During control of VC

 

(NOTE 1)

running)

 

 

 

 

and VP1 to VP3:

 

 

 

 

 

 

 

Warning level for power

 

 

 

 

 

 

 

running regenerative

 

 

 

 

 

 

 

overload

 

 

 

 

 

 

 

• When 0 is set: Any signal

 

 

 

 

 

 

 

is not output.

 

 

 

 

 

 

 

 

 

 

Overtorque

OV-TRQ R

100%

100%

0 to 250

• During control of SLV

 

 

signal rate

 

 

 

 

and V2: Regenerative

 

 

setting

 

 

 

 

overtorque level

 

 

(for regen-

 

 

 

 

• During control of VC

 

 

eration)

 

 

 

 

and VP1 to VP3: No

 

 

 

 

 

 

 

effect

 

 

 

 

 

 

 

• When 0 is set: Any signal

 

 

 

 

 

 

 

is not output.

 

 

 

 

 

 

 

 

27

F-34

Input

IN-TM 1

RS

RS reset

RS and 17

 

 

Intelligent

terminal 1

 

 

terminal

other terminals

 

 

terminal

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

input

Input

IN-TM 2

AT

AT current

AT and 17

 

 

terminal

terminal 2

 

 

input selection

other terminals

 

 

setting

setting

 

 

terminal

 

 

 

 

 

 

 

 

 

 

 

 

Input

IN-TM 3

JG

JG jogging

JG and17

 

 

 

terminal 3

 

 

terminal

other terminals

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

IN-TM 4

FRS

FRS free

FRS and 17

 

 

 

terminal 4

 

 

run

other terminals

 

 

 

setting

 

 

terminal

 

 

 

 

 

 

 

 

 

 

 

 

Input

IN TM 5

CH1

CH1 2-stage

CH1 and 17

 

 

 

terminal 5

 

 

acceleration

other terminals

 

 

 

setting

 

 

and

 

 

 

 

 

 

 

deceleration

 

 

 

 

 

 

 

terminal

 

 

 

 

 

 

 

 

 

 

NOTE 1: When setting 20% or less, the error will increase (± 20% or more).

Therefore, set 20% or more.

12-11

Page 102
Image 102
Hitachi J300U Series instruction manual 12-11