Hitachi J300U Series instruction manual Trouble shooting

Models: J300U Series

1 145
Download 145 pages 53.04 Kb
Page 79
Image 79

9.2Trouble shooting

Symptom

 

 

 

 

 

Probable cause

 

 

 

 

Countermeasure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The

The inverter

• Is power being supplied to terminals

• Check terminals R(L1), S(L2), T(L3), U(T1),

motor

outputs

 

R(L1), S(L2) and T(L3)?

V(T2), and W(T3).

will not

U(T1), V(T2)

 

If it is, the POWER lamp should be on.

• Turn on the power supply.

run.

and W(T3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

are not

• Is the display E * * ?

• Press

 

 

 

and check the content.

 

2

 

1

 

supplying

 

 

 

 

 

 

 

 

 

Then press the reset key.

 

voltage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Is the operation instruction RUN ON?

• Set to ON.

 

 

 

• Is terminal FW (or REV) connected to

• Connect terminal CM1 to terminal FW

 

 

 

terminal CM1?

(or REV) on the printed-circuit board.

 

 

 

 

 

 

 

 

 

 

(When the terminal mode is selected.)

 

 

 

• Has the frequency setter been turned on

• Push down keys and set.

 

 

 

 

 

 

 

 

 

 

• When terminal mode is selected, connect the

 

 

 

 

 

 

 

 

 

 

 

 

 

by pushing

FUNC

key and then

potentiometer to H, O, and L, and then set.

 

 

 

 

 

 

 

 

 

 

• In the case of the internal interface power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

1

key.

source, short the terminals P24 and PLC or

 

 

 

 

 

 

 

 

 

 

CM1 and PLC.

 

 

 

• Are the printed-circuit board terminals

 

 

 

• In the case of the external interface power

 

 

 

 

H, O and L connected to

 

 

 

 

source, turn the PLC terminal on.

 

 

 

 

the potentiometer?

 

 

 

 

 

 

 

 

 

 

 

 

• Are the terminals connected to the

 

 

 

 

 

 

 

 

 

external and internal interface power

 

 

 

 

 

 

 

 

 

source the terminal mode is selected?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Has RS/FRS been left ON?

• Release reset.

 

 

 

• Contact FRS.

 

 

 

 

 

 

 

 

 

 

Is the mode key setting correct? • Read the explanation of the function mode once again. (Page 7-12) F9 frequency/run commanding method

 

Inverter

• Has the motor seized or is the load too

• Release seizure or lighten the load.

 

outputs

great?

• Test the motor independently.

 

U(T1), V(T2)

 

 

 

 

 

 

 

 

 

 

 

 

 

and W(T3)

 

 

 

 

 

 

 

 

 

 

 

 

 

are supplying

 

 

 

 

 

 

 

 

 

 

 

 

 

voltage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The optional

• Are the remote operator and equipment

• Check the operation of the optional remote

 

remote

body switched coorrectly ?

operator. (copy unit)

 

operator is

• Is the setting of the DIP switch on the

 

 

 

 

 

 

 

 

 

 

 

 

used.

back of the remote operator correct ?

 

 

 

 

 

 

 

 

 

 

 

 

ON

1 2 3 4

 

 

 

(copy unit)

 

 

1: OFF

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2: ON (Same as VWA, J100)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The

• Are the connections of output terminals

• Make the connections according to the phase

direction

U(T1), V(T2) and W(T3) correct?

sequence of the motor. (In general, forward

of the

• Is the phase sequence of the motor

should be in the sequence: U(T1), V(T2)

motor is

forward or reverse in respect to U(T1),

and W(T3).)

 

reversed.

V(T2) and W(T3)?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Are the terminals on the printed-circuit

• Short the FW terminal for forward rotation or

 

 

board correct?

the intelligent input terminal 8 (the intelligent

 

 

 

input terminal 8 is allocated to run command

 

 

 

REV by initialization at factory before

 

 

 

shipment) for reverse rotation to the CM1

 

 

 

terminal (Sink type).

9-6