11.STANDARD SPECIFICATIONS
11.1Common Standarsd Specifications
|
| Item |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Description |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Input voltage |
|
|
|
|
|
|
|
| 200 V class |
|
|
|
|
|
|
|
|
|
|
|
|
| 400 V class |
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Model Name (Type) |
| 055 | 075 | 110 | 150 | 220 | 300 | 370 | 450 | 550 |
| 055 | 075 | 110 | 150 | 220 |
| 300 | 370 | 450 | 550 | 750 | 900 | 1100 | 1320 | 1600 | 2200 | |||||||||||
| LF | LF |
| LF | LF | LF | LF | LF | LF | LF |
| HF | HF |
| HF | HF | HF |
| HF | HF | HF | HF | HF | HF | HF | HF | HF | HF | ||||||||||
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||||||||
Enclosure (NOTE 1) | Semienclosed | Open type (IP00) |
| Semienclosed |
|
|
|
|
|
|
| Open type (IP00) |
|
|
| |||||||||||||||||||||||
| type (IP20) |
| type (IP20) |
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Rated AC input power supply (V) |
|
|
|
|
|
| ||||||||||||||||||||||||||||||||
200 to 230 V±10%, 50 or 60 Hz±5% |
|
|
| 400 to 460 V±10%, 50 or 60 Hz±5% |
|
|
| |||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Rated output voltage (V) (NOTE 2) |
|
|
|
|
|
|
|
| ||||||||||||||||||||||||||||||
(Corresponding to the input voltage) |
|
|
| (Corresponding to the input voltage) | ||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
| |||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Output frequency range (NOTE 3) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0.1 to 400 Hz |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Frequency accuracy |
| Digital command ±0.01% and analog command ±0.1% for the maximum |
|
|
| |||||||||||||||||||||||||||||||||
| frequency command |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Frequency setting resolution | Digital setting: 0.01 Hz/60 Hz, Analog setting: Maximum frequency/1000 | |||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Voltage/frequency characteristics | V/f variable, high start torque, standard starting torque (constant torque, |
|
|
| ||||||||||||||||||||||||||||||||||
reduced torque) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Acceleration/deceleration time | 0.01 to 3000 seconds, acceleration and deceleration individually set |
|
|
| ||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Starting torque (NOTE 4) |
|
|
|
|
|
|
|
|
|
|
|
| 150% or more (1 Hz) |
|
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Brak- | Dynamic braking | About |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
(NOTE 5) |
| About 10 to 20% |
| About 20% |
|
|
|
|
| About 10 to 15% |
|
|
| |||||||||||||||||||||||||
ing |
| 20% |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||
torque | Feedback to capacitor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| Dynamic braking using |
| Braking resistor optional for 055 and |
|
| Braking resistor optional for 055 and |
|
|
| ||||||||||||||||||||||||||||
|
| external resistor or unit |
| 075L, use braking unit (BRD) for |
|
| 075H, use braking unit (BRD) for |
|
|
| ||||||||||||||||||||||||||||
|
| (BRD) |
|
| 220 to 550L. |
|
|
|
|
|
|
|
| 220 to 2200H. |
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||
|
| DC injection braking |
| Operated at the DC braking frequency or by external input |
|
|
|
|
|
|
| |||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Input | Frequency |
| Digital operator |
|
|
|
|
|
|
|
|
|
|
|
|
| Set by |
|
| and |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
| 2 |
|
|
|
|
|
|
|
|
|
|
| ||||||||||
signals | setting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| 2 W 500 Ω to 2 kΩ potentiometer, 0 to 5 VDC (nominal), |
|
|
|
|
|
|
| |||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||||
|
|
|
| External signals | 0 to 10 VDC (nominal) (input impedance 30 kΩ), 4 to 20 mA (nominal) |
|
|
| ||||||||||||||||||||||||||||||
|
|
|
|
| (input impedance 250 Ω) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||
|
| Forward/ |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||
|
|
| Digital operator |
| RUN | / | STOP | (Only for forward run or reverse run, the function mode |
|
|
| |||||||||||||||||||||||||||
|
| reverse |
| should be switched.) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
| run, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| External signals | FW (forward run command)/stop |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
|
| stop |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||
|
|
|
|
| REV (reverse run command), FRS (free run stop command), CF1 to CF3 |
|
|
| ||||||||||||||||||||||||||||||
|
|
|
|
| (multistage speed setting), USP (USP function), JG (jogging command), |
|
|
| ||||||||||||||||||||||||||||||
|
|
|
|
| CH1 | |||||||||||||||||||||||||||||||||
|
| Intelligent input terminal | RS(reset input), STN (initialization), SFT (software lock), AT (current input | |||||||||||||||||||||||||||||||||||
|
|
|
|
| selection), CS (commercial power source switching), SET (2nd setting |
|
|
| ||||||||||||||||||||||||||||||
|
|
|
|
| selection), EXT (external trip), UP (remote control, acceleration), |
|
|
| ||||||||||||||||||||||||||||||
|
|
|
|
| DOWN (remote control, deceleration) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||
Output | Intelligent output terminal | FA1 (speed arrival signal), RUN (signal during run), OTQ (overtorque signal) | ||||||||||||||||||||||||||||||||||||
signals |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| Analog output frequency monitor (0 to 10 VDC full scale,1mA max.), digital | |||||||||||||||||||||||||||||||||||
|
|
|
|
| ||||||||||||||||||||||||||||||||||
|
| Frequency monitoring | frequency signal by remote operator, analog current monitor, analog torque | |||||||||||||||||||||||||||||||||||
|
|
|
|
| monitor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|