11.STANDARD SPECIFICATIONS

11.1Common Standarsd Specifications

 

 

Item

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input voltage

 

 

 

 

 

 

 

 

200 V class

 

 

 

 

 

 

 

 

 

 

 

 

 

400 V class

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model Name (Type)

 

055

075

110

150

220

300

370

450

550

 

055

075

110

150

220

 

300

370

450

550

750

900

1100

1320

1600

2200

 

LF

LF

 

LF

LF

LF

LF

LF

LF

LF

 

HF

HF

 

HF

HF

HF

 

HF

HF

HF

HF

HF

HF

HF

HF

HF

HF

 

 

 

 

 

 

 

 

 

Enclosure (NOTE 1)

Semienclosed

Open type (IP00)

 

Semienclosed

 

 

 

 

 

 

 

Open type (IP00)

 

 

 

 

type (IP20)

 

type (IP20)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated AC input power supply (V)

Three-phase (3 wires), 200 to 220 or

 

 

 

Three-phase (3 wires), 380 to 415 or

 

 

 

200 to 230 V±10%, 50 or 60 Hz±5%

 

 

 

400 to 460 V±10%, 50 or 60 Hz±5%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated output voltage (V) (NOTE 2)

Three-phase, 200 to 230 V

 

 

 

 

 

Three-phase, 380 to 460 V

 

 

 

(Corresponding to the input voltage)

 

 

 

(Corresponding to the input voltage)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output frequency range (NOTE 3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1 to 400 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency accuracy

 

Digital command ±0.01% and analog command ±0.1% for the maximum

 

 

 

 

frequency command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency setting resolution

Digital setting: 0.01 Hz/60 Hz, Analog setting: Maximum frequency/1000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage/frequency characteristics

V/f variable, high start torque, standard starting torque (constant torque,

 

 

 

reduced torque)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Acceleration/deceleration time

0.01 to 3000 seconds, acceleration and deceleration individually set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Starting torque (NOTE 4)

 

 

 

 

 

 

 

 

 

 

 

 

150% or more (1 Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brak-

Dynamic braking

About

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(NOTE 5)

 

About 10 to 20%

 

About 20%

 

 

 

 

 

About 10 to 15%

 

 

 

ing

 

20%

 

 

 

 

 

 

 

 

 

 

 

 

torque

Feedback to capacitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dynamic braking using

 

Braking resistor optional for 055 and

 

 

Braking resistor optional for 055 and

 

 

 

 

 

external resistor or unit

 

075L, use braking unit (BRD) for

 

 

075H, use braking unit (BRD) for

 

 

 

 

 

(BRD)

 

 

220 to 550L.

 

 

 

 

 

 

 

 

220 to 2200H.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC injection braking

 

Operated at the DC braking frequency or by external input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

Frequency

 

Digital operator

 

 

 

 

 

 

 

 

 

 

 

 

 

Set by

 

 

and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

 

 

 

 

 

 

 

 

 

 

 

signals

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 W 500 Ω to 2 kΩ potentiometer, 0 to 5 VDC (nominal),

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External signals

0 to 10 VDC (nominal) (input impedance 30 kΩ), 4 to 20 mA (nominal)

 

 

 

 

 

 

 

 

(input impedance 250 Ω)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Forward/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital operator

 

RUN

/

STOP

(Only for forward run or reverse run, the function mode

 

 

 

 

 

reverse

 

should be switched.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

run,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External signals

FW (forward run command)/stop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REV (reverse run command), FRS (free run stop command), CF1 to CF3

 

 

 

 

 

 

 

 

(multistage speed setting), USP (USP function), JG (jogging command),

 

 

 

 

 

 

 

 

CH1 (2-stage acceleration and deceleration), DB (external DB command),

 

 

Intelligent input terminal

RS(reset input), STN (initialization), SFT (software lock), AT (current input

 

 

 

 

 

selection), CS (commercial power source switching), SET (2nd setting

 

 

 

 

 

 

 

 

selection), EXT (external trip), UP (remote control, acceleration),

 

 

 

 

 

 

 

 

DOWN (remote control, deceleration)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Intelligent output terminal

FA1 (speed arrival signal), RUN (signal during run), OTQ (overtorque signal)

signals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Analog output frequency monitor (0 to 10 VDC full scale,1mA max.), digital

 

 

 

 

 

 

 

Frequency monitoring

frequency signal by remote operator, analog current monitor, analog torque

 

 

 

 

 

monitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11-1