Service Tests and Utilities

4If you press Enter, the Front Panel will display a list of the different results you can view. You can make your selection using the arrow keys and press Enter to view the selection.

Test results. Select item for more information

PWM

Speed offset Stabilization distance

Menu

Back

Enter

5If you selected PWM, the Front Panel will display the results of the PWM test:

 

 

 

 

 

PWM results

 

 

 

 

 

Average value of the PWM

 

Average: XXX

Standard deviation value of

 

the PWM

 

Std dev: X

 

 

 

 

 

 

6If you selected Speed offset, the Front Panel will display the results of the Speed offset:

 

Speed offset results

 

 

 

 

 

Average value of the speed offset

 

Average (ips): X

Standard deviation value of

 

Std dev (ips): X

the speed offset

7If you selected Stabilization distance, the Front Panel will display the results of the Stabilization distance:

Stabilization distance results

Stabilizat. dist. (mm): XX

To check if the values displayed after the test are within the limits, refer to the following table:

 

Normal Values

Acceptable Values

 

 

 

PWM Average

Between 95 and 115

< 150

 

 

 

PWM Std dev

< 10

< 15

 

 

 

Speed Offset Average

0

0

 

 

 

HP DesignJets 500, 510 and 800 Series Printers Service Manual

4-9

Page 79
Image 79
HP 510 Inkjet Large Format CH336A#B1K manual Normal Values Acceptable Values PWM Average