SIMM Validation Error Messages

Validation error messages appear when a SIMM fails to be initialized when the printer is turned on. This error is in the format 53.XY.ZZ ERROR. Table 7-1 lists these errors.

Table 7-1

Validation Error Messages

 

 

 

X (Hardware Type)

Y (Hardware Device)

ZZ (Error Number)

 

 

 

 

0: ROM

 

0: Internal Memory

0: Unsupported memory

1: RAM

 

1: SIMM Slot 1

1: Unrecognized memory

 

 

2: SIMM Slot 2

2: Unsupported memory size

 

 

3: SIMM Slot 3

3: Failed RAM test

 

 

4: SIMM Slot 4

4: Exceeded maximum RAM size

 

 

 

5: Exceeded maximum ROM size

 

 

 

6: Invalid SIMM speed

 

 

 

7: SIMM reporting information incorrectly

 

 

 

8: SIMM RAM parity error

 

 

 

9: (n/a)

 

 

 

10: SIMM address conflict

 

 

 

11: ROM out of bounds

 

 

 

12: Could not make temporary mapping

 

 

 

 

Although these errors can be ignored, the SIMM that caused the error will not be configured. If the SIMM causing the error is a RAM SIMM, the printer will continue to function with less RAM. If the SIMM is a ROM containing a printer personality (such as PostScript) the printer will continue but without that personality.

7 Maintenance & Troubleshooting

EN

Maintenance and Troubleshooting 7-21

Page 134
Image 134
HP 5Si NX, 5Si MX manual Simm Validation Error Messages, Hardware Type Hardware Device ZZ Error Number