Introduction

1

2

3

2

3

1

Cooling fan (4)

 

3 Power switches on power supplies

2

Power supply (2)

 

(2)

 

 

 

 

Figure 1–3: Edge Switch 2/32 (Rear View)

SFP Transceivers

A single-mode or multi-mode fiber-optic cable attaches to a port through a pluggable small form factor (SFP) transceiver. The SFP provides a duplex LC interface, and can be detached from the switch port for easy replacement. Two fiber-optic transceiver types are available:

Shortwave laser — Shortwave laser SFPs provide short-distance connections (2 to 500 meters) through 50-micron or 62.5-micron multi-mode fiber.

Longwave laser — Longwave laser SFPs provide long-distance connections (up to 10 kilometers) through 9-micron single-mode fiber.

Cooling Fans

Four fans (each a separate FRU) provide cooling for the switch power supplies and the control processor (CTP) card, as well as redundancy for continued operation if a single fan fails.

Each fan FRU can be replaced while the switch is operating.

Power Supplies

Redundant, load-sharing power supplies step down and rectify facility input power to provide 3.3 volts direct current (VDC), 5 VDC, and 12 VDC to the CTP. The power supplies also provide input filtering, overvoltage protection, and overcurrent protection. Either power supply can be replaced while the switch is operational.