Installing and Configuring the Edge Switch 2/32

Configure Switch and Fabric Parameters

Perform this procedure to configure the following switch and fabric operating parameters: Buffer-to-Buffer Credit (BB_Credit), Error Detect Time Out Value (E_D_TOV), and Resource Allocation Time Out Value (R_A_TOV), preferred domain ID and switch priority.

Configure Switch Parameters

The switch must be set offline to configure operating parameters. To configure the parameters:

1.Set the switch offline as follows:

a.At the View panel, select Operations at the left side of the panel. The Operations panel opens with the Switch Beacon page displayed.

b.At the Current State window, click Set Offline. The message Your operations changes have been successfully activated displays.

2.At the View panel, select Configure at the left side of the panel. The Configure panel opens with the Ports page displayed.

3.At the Configure panel, click the Switch tab, then select Parameters. The Switch page displays with Switch Parameters displayed.

4.Set the switch parameters: