Installing and Configuring the Edge Switch 2/32

Figure 2–24: Configure Addresses—Active dialog box

a.Select a blank Name field and type a descriptive port name of 24 or fewer alphanumeric characters. Use a name that reflects the device connected to the port.

b.Click Blocked to block or unblock a port. A check mark in the box indicates the port is blocked. Blocking the port prevents the attached device from communicating with the switch. A blocked port continuously transmits the offline sequence (OLS).

2.The yellow shaded area of the dialog box (matrix) represents a rectangular array of port addresses used to configure connections. The default state is an empty cell representing an allowed connection between two port addresses.

a.Click a blank matrix cell to prohibit the connection of the two intersecting ports. A prohibited connection is indicated by a red circle with a slash in the cell.

b.Click a prohibited matrix cell to clear the restriction and allow the connection of the two intersecting ports.

c.Right-click a matrix cell to display a menu that provides the following port configuration selections: