Troubleshooting

Solving Problems with Plot Position or Content

If the Output Contains Only a Partial Plot

Did you press Form Feed and Cut before all the data was received by the plotter? If so, you have ended the data transmission and will have to print the plot again. (You normally don't need to press Form Feed and Cut to unload the plot.)

The I/O Setup / I/O Timeout setting may be too short. Increase the setting and plot again. See page 7-9.

The file may be too big for the plotter's memory. For information on memory expansion modules, see page 11-14.

There may be a communications problem between your computer and the plotter. Make sure interface cable is connected properly.

Check to make sure that your software settings are correct for your current plot size (e.g., long-axis plots).

If you are using network software, make sure it has not timed out.

See also under ªIf the plot is clippedº on page 9-12.

9 TROUBLE- SHOOTING