Message | Explanation and Action |
Lower lever | You lifted the media lever while the processor was busy. Lower the lever to |
to continue | continue. |
|
|
Lower window | You opened the window while the processor was busy. Close the window to |
to continue | continue. |
|
|
Media too small | The media you loaded for accuracy calibration or cartridge alignment is too small. |
| Reload appropriate media. See page |
|
|
Mispositioned | The roll is mispositioned. Reload media. |
Reload roll |
|
|
|
Mispositioned | The sheet is mispositioned. Remove it and reload it with the right edge no more |
Reload sheet | than 0.2 inches (0.5 cm) from either side of the perforated line on the entry platen. |
|
|
MIO data error | The modular interface is incorrectly configured. Press Enter to clear the message |
| from the front panel display. Recheck the MIO configuration settings. |
|
|
MIO error | The flow of data from the computer to the plotter was prematurely stopped (e.g., |
Communication | by turning off the computer before all data is sent). Press Enter to clear the |
Break | message from the front panel display. |
|
|
Open window to | Lift the window to access the cartridge(s). |
access cartridge(s) |
|
|
|
Out of memory | The current plot is too large for the plotter's buffer. Install additional memory to |
Data was lost | plot this drawing. |
|
|
Pull # / Align $ | Grasp the left and right free edges of the roll media and pull toward you until the |
edges to roll | media is taut. At the same time, align the left and right edges of the media so that |
| they are flush with the left and right edges of the roll. |
|
|
Remove media | The ink is dry. Remove the calibration plot the plotter just produced. Press ↓ to |
| continue with accuracy calibration. |
|
|
Remove media | You have attempted to load media while the lever at the right of the plotter was |
Lower lever | raised. Remove the media, lower the lever, and reload media with the lever down. |
|
|
Replace cartridge(s) | The cartridge indicated has a clogged nozzle. Replace it to continue. |
| |
|
|
Reseat cartridge(s) | The cartridge indicated is badly seated. Reseat it to continue. |
| |
|
|
Roll misaligned | Roll media is misaligned (skewed). Reload media. |
Reload roll |
|
|
|
The | |
Baud, parity | message from the front panel display. Check the baud rate and parity settings in |
| the front panel, in the hardware configuration, and in your software to be sure they |
| are all compatible. |
|
|
10 MESSAGES