Front-Panel Messages

 

 

Front-Panel Messages

 

 

This is a list of all possible messages in the front-panel display. If you need to do

 

 

something, it is shown in italics in the Explanation and Action column.

 

 

The messages are listed in alphabetical order.

 

 

 

Message

 

Explanation and Action

 

 

 

Alignment error

 

The alignment procedure has failed. Check that an opaque media is loaded.

Continue

 Press to continue and force the automatic alignment procedure again by

 

 

reseating any of the print cartridges. Do not lift the window while cartridge

 

 

alignment is being performed.

 

 

 

Calibrate error

 

The calibration plot was loaded incorrectly and it could not be measured. Press

Continue

 to continue, then reload the plot for measurement. Follow front panel instructions.

 

 

 

Calibration done

 

Accuracy calibration is complete. Press to continue.

Continue



 

 

 

 

Close roll cover

 

Rewind the media to take up any slack in the roll, close the roll cover, then press

Continue



to continue.

 

 

Create pattern

 Press to create the pattern for automatic calibration.

Measure pattern



Press to start the automatic calibration.

 

 

 

Edge not found

 

The plotter could not find edge of media during loading procedure. Check the

Reload media

 

leading edge of the media for unevenness or tears; cut a straight edge, if

 

 

necessary, and reload. Be sure to position the right edge along the perforated line

 

 

on the entry platen when loading.

 

 

 

Lift lever

 

Lift the lever at the right of the plotter.

 

 

 

Load arrow edge

 

Remove calibration plot, turn it so that the edge with arrows printed on it is print

print side down

 

side down, then load that edge into the plotter.

 

 

 

Load cancelled

 

You pressed the Cancel button while media loading was in progress. Remove

Remove media

 

media.

 

 

 

Load error

 

You inserted media with the media lever raised. Lower the lever and reload the

Remove media

 

media.

 

 

 

Load media

 

Load media to proceed with cartridge alignment.

to align cartridges

 

 

 

 

 

Lower lever

 

When you have finished aligning the roll media as instructed, lower the lever at

after aligning

 

the right of the plotter.

 

 

 