8.2.2 DS Management Console connectivity

Connectivity to the DS6000 series from the DS Management Console is needed to perform configuration updates to the DS6000 series. Connectivity to both DS6800 controllers is required to activate updates.

Figure 8-1illustrates the DS Management console, optionally connected to to the DS6000 by redundant Ethernet switches, but redundant switches are not a requirement. The switches must be part of the same subnet so that the controllers in the DS6000 can communicate with each other through the Ethernet.

 

Switch Connection

 

 

Client's Ethernet switch

 

 

standard

 

 

Ethernet

DS Management Console

 

cables

DS6000 series

 

Redundant Ethernet switch

 

 

 

inter-switch link

 

 

 

Alternate DS Management Console

Figure 8-1 Network configuration for DS Management Console

8.2.3 Local maintenance

The DS6000 series is a customer maintained system. No IBM SSR (Service Support Representative) is involved, unless you have a service contract with IBM. The customer does problem determination, replacement parts ordering, and the actual replacement of the component. Most components are customer replaceable units (CRUs).

In the event of a failure, the following sequence of events takes place:

￿A fault conditions occurs, for example, a power supply failure.

￿The user is alerted about the failure.

￿The user hyperlinks to the component view and identifies the failing component. In this case, it is a power supply.

￿The user reviews component removal instructions.

￿The user reviews the component installation instructions for the new power supply.

￿Before removing a faulty component, ensure that you have a replacement component available on site.

￿Remove the faulty power supply from the DS6000 as per the instructions.

￿Install the new power supply.