Indicator | Symbol | Purpose |
|
|
|
DC Power (green) | DC | If this indicator is on solid then the power supply is |
|
| producing correct DC power. If it is blinking then the |
|
| DS6000 is not powered on. If it is off then either the |
|
| enclosure is powered off or the power supply is faulty. |
|
|
|
Fault detected | Exclamation mark | If this indicator is on solid then the DS6000 has |
(yellow) |
| identified this power supply as being faulty and it |
|
| requires replacement. |
|
|
|
2.9.1 Battery backup units
Each DS6800 RAID controller has a battery backup unit (BBU) to provide DC power to that controller in the event of a complete loss of power. There are thus two BBUs present in the DS6800 server enclosure. If you compare their function to that of the different batteries in the ESS, they are the NVS batteries. They allow
From the rear of the unit, the
DC |
present |
Fault |
detected |
Battery |
charging |
Figure 2-19 DS6000 battery backup unit indicators
The DS6000 battery units have three indicators, detailed in Table
Table 2-4 DS6800 battery backup unit indicators
Indicator | Symbol | Purpose |
|
|
|
DC present | Lightning bolt | If this indicator is on solid then DC power is present. If |
(green) |
| this indicator is off then DC power is not available from |
|
| this battery. |
|
|
|
Chapter 2. Components 41